Victrex PEEK 450GL30 is a 30% glass-fiber-reinforced PEEK for applications where stiffness and dimensional behavior matter. This page connects the manufacturer datasheet to molding decisions: directional shrinkage, mold temperature, drying and part-level validation. HDT is a test result, not a continuous service-temperature guarantee. Send the drawing, operating conditions and quantity for a molding review.

High-precision-injection-molded-black-30-glass-filled-PEEK-structural-brackets-made-from-Victrex-PEEK-450GL30

Data source: Victrex 450GL30 technical datasheet, March 2026 revision (PDF), checked 29 September 2026. This page uses that revision consistently; older documents may show different nominal values. See the manufacturer document for complete test methods and limitations.

Victrex PEEK 450GL30 Properties and Datasheet

Victrex PEEK 450GL30 is a semi-crystalline PEEK containing 30% glass fiber. Its stiffness and directional shrinkage are relevant when selecting a resin for loaded components. The values below are material comparison data; they do not establish the allowable load or dimensional tolerance of a finished part.

المعامل الميكانيكي/الحراري Nominal Value / Test Condition How to Interpret the Result
الصلابة الهيكلية معامل الشد 11,500 ميجا باسكال / قوة الانحناء 275 ميجا باسكال Tensile modulus is measured at 23°C under ISO 527-1; flexural stress is measured under ISO 178. Deflection still depends on geometry, temperature, fiber orientation and loading time. Check creep and fatigue separately for sustained or cyclic loads.
انحراف الحرارة (HDT) 328°C at 1.8 MPa, unannealed (ISO 75-2/Af) HDT is a short-duration test under a specified load. It is not a continuous operating-temperature rating or a guarantee against deformation in service.
التمدد الحراري الخطي CLTE along flow: 18 ppm/K below 143°C (ISO 11359-2) Expansion is directional. Check the actual flow pattern and temperature range when designing fits or seals; a flow-direction value alone cannot predict the movement of an entire molded part.

Application Screening: What Must Be Verified

Assess grade suitability against the drawing and operating environment. The following checks help identify the application tests required before committing to tooling.

Candidate Application Questions Before Selecting the Grade
مكونات هيكلية للفضاء What are the load direction, temperature and fatigue requirements? Evaluate weld-line location, fiber orientation and part-level qualification before specifying a structural bracket.
حشوات النفط والغاز أسفل البئر Specify pressure, media, exposure time and mating surfaces. Chemical compatibility, creep and sealing performance require application testing; a resin datasheet cannot establish a pressure rating.
صواني مناولة أشباه الموصلات Confirm contamination, outgassing, electrostatic and thermal-cycling limits. Do not infer low-outgassing or ESD compliance from glass reinforcement alone.

Injection Molding: Shrinkage, Drying and Mold Temperature

The process window must be established for the actual tool and machine. The manufacturer settings below are starting points for trials, not a validated production recipe for every geometry.

التحكم في تآكل الأدوات الكاشطة

Glass reinforcement can increase wear at gates, runners and other high-flow regions. Review tool steel, surface treatment and replaceable wear features against the expected volume and maintenance plan. A fixed hardness or coating cannot guarantee tool life for every part.

إدارة الانكماش والالتواء غير المتناحي

The March 2026 Victrex datasheet lists 0.30% shrinkage along flow and 0.90% across flow under ISO 294-4, using a 385°C nozzle and 190°C tool. These are test-specimen results. Gate position, wall transitions and packing change local fiber orientation and shrinkage, so cavity allowances require mold-flow review and measurements from trial parts.

Mold Temperature and Crystallization

Victrex lists a typical mold-temperature range of 180–200°C. Choose a heating system rated for the required temperature and check cavity-surface uniformity. Cooling history affects crystallization and dimensions; validate the actual process instead of relying only on the controller setpoint.

بروتوكول التجفيف الممتد باستخدام المجففات

The manufacturer specifies drying at 150°C for 3 hours or 120°C for 5 hours, with residual moisture below 0.02%. Confirm dryer performance and resin handling before molding. Measure residual moisture before trials and record the resin lot, drying history and handling conditions for repeat production.

Information Needed for a 450GL30 Molding Review

  • Part requirements: Supply the drawing, CAD model, critical dimensions, datums and load direction. Identify sustained loads and expected service life.
  • Service conditions: Define the temperature range, chemical exposure, pressure and any sterilization or thermal cycling. Explain how acceptance will be tested.
  • Procurement and validation: State the quantity, exact resin grade and color, traceability requirements and inspection documentation. Agree on trial-part validation before approving production.

الخصائص

Density, crystalline (ISO 1183) 1.51 g/cm³
لزوجة الذوبان (400 درجة مئوية) 550 Pa·s
معامل الشد (23°م) 11.5 GPa
Tensile Stress at Break, 23°C (ISO 527-2) 179 MPa
Tensile Strain at Break, 23°C (ISO 527-2) 3.0 %
مقاومة الانحناء (23°م) 275 MPa
معامل الانحناء (23°م) 11 GPa
Compressive Strength (23°C) 250 MPa
قوة تأثير شاربي المحززة (23°م) 8 كيلوجول/م²
Notched Izod, 23°C (ISO 180/A) 10.0 kJ/m²
درجة حرارة الانصهار 343 درجة مئوية
درجة حرارة الانتقال الزجاجي (البداية) 143 درجة مئوية
HDT, 1.8 MPa, unannealed (ISO 75-2/Af) 328 °C
Mold Shrinkage, Flow (ISO 294-4) 0.30 %
Mold Shrinkage, Across Flow (ISO 294-4) 0.90 %
معدل الاشتعال (1.5 مم) UL 94 V-0 فئة
الحد الأقصى لحجم الجزء 800 × 600 مم
الحد الأدنى لحجم الجزء 1 × 1 مم