{"id":2568,"date":"2026-06-17T16:53:35","date_gmt":"2026-06-17T08:53:35","guid":{"rendered":"https:\/\/www.jcinjectionmolding.com\/?p=2568"},"modified":"2026-06-30T14:21:46","modified_gmt":"2026-06-30T06:21:46","slug":"coc-topas-5013","status":"publish","type":"material_model","link":"https:\/\/www.jcinjectionmolding.com\/vi\/materials\/biocompatible-medical-grade-resin\/coc-topas-5013\/","title":{"rendered":"COC-TOPAS 5013"},"content":{"rendered":"<div class=\"material-page-wrapper\" style=\"line-height: 1.7 !important;letter-spacing: 0.03em !important;, Arial, sans-serif !important;color: #333333 !important\">\n<p><!-- 3. \u6750\u6599\u4e0b\u5c5e\u578b\u53f7\u4ecb\u7ecd\uff08\u8868\u683c\uff09 --><\/p>\n<section class=\"material-grades\">\n<h2 style=\"font-size: 26px !important;color: #111111 !important;margin-top: 35px !important;margin-bottom: 18px !important;font-weight: 600 !important;letter-spacing: 0.04em !important\">TOPAS 5013S-04 Optical Clarity &amp; Regulatory Compliance Profile<\/h2>\n<p style=\"margin-bottom: 18px !important;color: #4a4a4a !important\">TOPAS\u00ae 5013S-04 is a high flow, unreinforced amorphous Cyclic Olefin Copolymer (COC) resin engineered by Polyplastics, certified to deliver outstanding light transmission, low birefringence, and high heat resistance for MedTech applications:<\/p>\n<table style=\"width: 100% !important;border-collapse: collapse !important;margin-top: 20px !important;margin-bottom: 30px !important;border: 1px solid #a0b8b2 !important\">\n<thead>\n<tr>\n<th style=\"background-color: #edf4f9 !important;color: #111111 !important;font-weight: 600 !important;padding: 14px 18px !important;border: 1px solid #a0b8b2 !important;text-align: left !important;letter-spacing: 0.04em !important;line-height: 1.7 !important\">Physical &amp; Optical Attribute<\/th>\n<th style=\"background-color: #edf4f9 !important;color: #111111 !important;font-weight: 600 !important;padding: 14px 18px !important;border: 1px solid #a0b8b2 !important;text-align: left !important;letter-spacing: 0.04em !important;line-height: 1.7 !important\">TOPAS 5013S-04 Value<\/th>\n<th style=\"background-color: #edf4f9 !important;color: #111111 !important;font-weight: 600 !important;padding: 14px 18px !important;border: 1px solid #a0b8b2 !important;text-align: left !important;letter-spacing: 0.04em !important;line-height: 1.7 !important\">MedTech &amp; Optical Advantage<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"padding: 14px 18px !important;border: 1px solid #a0b8b2 !important;color: #4a4a4a !important;line-height: 1.7 !important;font-weight: bold\">Light Transmittance<\/td>\n<td style=\"padding: 14px 18px !important;border: 1px solid #a0b8b2 !important;color: #4a4a4a !important;line-height: 1.7 !important\">92.0% Optical Transmission (at 589nm)<\/td>\n<td style=\"padding: 14px 18px !important;border: 1px solid #a0b8b2 !important;color: #4a4a4a !important;line-height: 1.7 !important\">Delivers glass-matching transparency and high refractive index directly from polished mold cavities, ideal for diagnostic cuvettes.<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 14px 18px !important;border: 1px solid #a0b8b2 !important;color: #4a4a4a !important;line-height: 1.7 !important;font-weight: bold\">Extreme Hydrophobicity<\/td>\n<td style=\"padding: 14px 18px !important;border: 1px solid #a0b8b2 !important;color: #4a4a4a !important;line-height: 1.7 !important\">Water Absorption 0.010% (at 23\u00b0C saturation)<\/td>\n<td style=\"padding: 14px 18px !important;border: 1px solid #a0b8b2 !important;color: #4a4a4a !important;line-height: 1.7 !important\">Virtually non-hygroscopic. Excludes environmental moisture swelling or volume shifting, preventing micro-volume diagnostic errors.<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 14px 18px !important;border: 1px solid #a0b8b2 !important;color: #4a4a4a !important;line-height: 1.7 !important;font-weight: bold\">L\u00e0m m\u1ec1m nhi\u1ec7t<\/td>\n<td style=\"padding: 14px 18px !important;border: 1px solid #a0b8b2 !important;color: #4a4a4a !important;line-height: 1.7 !important\">Vicat B50 Softening Temp 125\u00b0C<\/td>\n<td style=\"padding: 14px 18px !important;border: 1px solid #a0b8b2 !important;color: #4a4a4a !important;line-height: 1.7 !important\">Maintains absolute structural stiffness and flat dimensional replication up to 130\u00b0C, fully resisting 95\u00b0C thermal PCR cycles.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/section>\n<p><!-- 4. \u6750\u6599\u6240\u5e94\u7528\u7684\u5de5\u827a\u4ecb\u7ecd\uff08\u8868\u683c\uff09 --><\/p>\n<section class=\"molding-processes\">\n<h2 style=\"font-size: 26px !important;color: #111111 !important;margin-top: 35px !important;margin-bottom: 18px !important;font-weight: 600 !important;letter-spacing: 0.04em !important\">Biocompatible Process Configurations for Easy-Flow TOPAS 5013<\/h2>\n<p style=\"margin-bottom: 18px !important;color: #4a4a4a !important\">With outstanding melt fluidity and amorphous stability, TOPAS 5013S-04 processes consistently inside microfluidic tools:<\/p>\n<table style=\"width: 100% !important;border-collapse: collapse !important;margin-top: 20px !important;margin-bottom: 30px !important;border: 1px solid #a0b8b2 !important\">\n<thead>\n<tr>\n<th style=\"background-color: #faf6f5 !important;color: #111111 !important;font-weight: 600 !important;padding: 14px 18px !important;border: 1px solid #a0b8b2 !important;text-align: left !important;letter-spacing: 0.04em !important;line-height: 1.7 !important\">Molding Process Category<\/th>\n<th style=\"background-color: #faf6f5 !important;color: #111111 !important;font-weight: 600 !important;padding: 14px 18px !important;border: 1px solid #a0b8b2 !important;text-align: left !important;letter-spacing: 0.04em !important;line-height: 1.7 !important\">Process Compatibility &amp; Operational Details<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"padding: 14px 18px !important;border: 1px solid #a0b8b2 !important;color: #4a4a4a !important;line-height: 1.7 !important;font-weight: bold\">Microfluidic Lab-on-a-Chip<\/td>\n<td style=\"padding: 14px 18px !important;border: 1px solid #a0b8b2 !important;color: #4a4a4a !important;line-height: 1.7 !important\">Excellent. The primary process for TOPAS 5013. Optimized for multi-cavity, ultra-thin-walled medical diagnostics and biochips down to 0.1mm channels.<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 14px 18px !important;border: 1px solid #a0b8b2 !important;color: #4a4a4a !important;line-height: 1.7 !important;font-weight: bold\">Precision Cuvettes &amp; Microplates<\/td>\n<td style=\"padding: 14px 18px !important;border: 1px solid #a0b8b2 !important;color: #4a4a4a !important;line-height: 1.7 !important\">Excellent. Highly compatible with high-speed automated runs, providing low-noise optical windows and excellent chemical-solvent resistance.<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 14px 18px !important;border: 1px solid #a0b8b2 !important;color: #4a4a4a !important;line-height: 1.7 !important;font-weight: bold\">High-Accuracy Lenses &amp; Optics<\/td>\n<td style=\"padding: 14px 18px !important;border: 1px solid #a0b8b2 !important;color: #4a4a4a !important;line-height: 1.7 !important\">Excellent. Low dielectric constant and low birefringence are perfect for molding precise spherical lenses and optical diffusers.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/section>\n<p><!-- 5. \u5236\u9020\u6280\u672f\u6307\u5357 --><\/p>\n<section class=\"manufacturing-guide\">\n<h2 style=\"font-size: 26px !important;color: #111111 !important;margin-top: 35px !important;margin-bottom: 18px !important;font-weight: 600 !important;letter-spacing: 0.04em !important\">Optical Birefringence &amp; Microfluidic Control Matrix<\/h2>\n<p style=\"margin-bottom: 18px !important;color: #4a4a4a !important\">Molding an amorphous high-purity, easy-flow polymer like TOPAS 5013S-04 requires strict particulate controls and specialized tooling to prevent optical strain:<\/p>\n<div style=\"border: 1px solid #a0b8b2 !important;margin-top: 20px !important;margin-bottom: 20px !important\">\n<div style=\"background-color: #edf4f9 !important;padding: 18px !important;border-bottom: 1px solid #a0b8b2 !important\">\n<p style=\"margin-bottom: 0px !important;color: #111111 !important;font-weight: bold;font-size: 15px !important\">Low Birefringence &amp; Stress Prevention<\/p>\n<p style=\"margin-top: 8px !important;margin-bottom: 0px !important;color: #4a4a4a !important;font-size: 14px !important\">High melt shear during injection causes internal molding stresses, resulting in birefringence (rainbow refraction effects). Jucheng&#8217;s tooling division uses 5-axis CNC machines to cut precise runner geometries, applying slow, uniform packing pressures to prevent optical stress marks.<\/p>\n<\/div>\n<div style=\"background-color: #faf6f5 !important;padding: 18px !important;border-bottom: 1px solid #a0b8b2 !important\">\n<p style=\"margin-bottom: 0px !important;color: #111111 !important;font-weight: bold;font-size: 15px !important\">S136 Mirror-Polished Tooling (Purity Preservation)<\/p>\n<p style=\"margin-top: 8px !important;margin-bottom: 0px !important;color: #4a4a4a !important;font-size: 14px !important\">Any microscopic tool mark on core or cavity surfaces will scatter light and compromise optical clarity. We build molds using high-chromium S136 stainless steel, mirror-polished to a high level using clean diamond paste, ensuring non-porous biocompatible part surfaces with zero particulates.<\/p>\n<\/div>\n<div style=\"background-color: #edf4f9 !important;padding: 18px !important;border-bottom: 1px solid #a0b8b2 !important\">\n<p style=\"margin-bottom: 0px !important;color: #111111 !important;font-weight: bold;font-size: 15px !important\">Pressurized Oil Mold Temperature Control<\/p>\n<p style=\"margin-top: 8px !important;margin-bottom: 0px !important;color: #4a4a4a !important;font-size: 14px !important\">We maintain mold temperatures at 95\u00b0C\u2013125\u00b0C (203\u00b0F to 257\u00b0F) using pressurized temperature controllers. High mold temperatures maximize surface gloss, reduce weld lines, and completely prevent weld-line stress cracking near intricate snap-fits.<\/p>\n<\/div>\n<div style=\"background-color: #faf6f5 !important;padding: 18px !important\">\n<p style=\"margin-bottom: 0px !important;color: #111111 !important;font-weight: bold;font-size: 15px !important\">Mandatory Desiccant Pre-Drying Protocol<\/p>\n<p style=\"margin-top: 8px !important;margin-bottom: 0px !important;color: #4a4a4a !important;font-size: 14px !important\">Though COC absorbs virtually zero water, pre-drying raw material in clean-air desiccant hopper dryers at 100\u00b0C (212\u00b0F) for 6 hours is mandatory to prevent surface splay, dynamic micro-voids, and loss of transparent optical quality during high-speed runs.<\/p>\n<\/div>\n<\/div>\n<\/section>\n<p><!-- 6. \u4e3b\u8981\u5e94\u7528\u884c\u4e1a\u9886\u57df --><\/p>\n<section class=\"key-applications\">\n<h2 style=\"font-size: 26px !important;color: #111111 !important;margin-top: 35px !important;margin-bottom: 18px !important;font-weight: 600 !important;letter-spacing: 0.04em !important\">Key Application Fields for COC-TOPAS 5013<\/h2>\n<ul style=\"padding-left: 20px !important;margin-bottom: 25px !important\">\n<li style=\"margin-bottom: 10px !important;color: #4a4a4a !important\"><strong>Medical Diagnostics &amp; Microfluidics:<\/strong> High-density microfluidic diagnostic chips, lab-on-a-chip diagnostic devices, cuvettes, assay plates, and pre-filled syringe barrels.<\/li>\n<li style=\"margin-bottom: 10px !important;color: #4a4a4a !important\"><strong>High-End Optics &amp; Lenses:<\/strong> Spherical and aspherical optical lenses, protective camera covers, light guides, and light diffusion plates.<\/li>\n<li style=\"margin-bottom: 10px !important;color: #4a4a4a !important\"><strong>High-Tech Electronic Enclosures:<\/strong> Low dielectric constant chip carrier trays, semiconductor handling packaging, and transparent display window plates.<\/li>\n<\/ul>\n<\/section>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>TOPAS 5013S-04 Optical Clarity &amp; Regulatory Compliance Profile TOPAS\u00ae 5013S-04 is a high flow, unreinforced amorphous Cyclic Olefin Copolymer (COC) resin engineered by Polyplastics, certified to deliver outstanding light transmission, low birefringence, and high heat resistance for MedTech applications: Physical &amp; Optical Attribute TOPAS 5013S-04 Value MedTech &amp; Optical Advantage Light Transmittance 92.0% Optical Transmission [&hellip;]<\/p>\n","protected":false},"featured_media":2519,"template":"","meta":[],"class_list":["post-2568","material_model","type-material_model","status-publish","has-post-thumbnail","hentry"],"_links":{"self":[{"href":"https:\/\/www.jcinjectionmolding.com\/vi\/wp-json\/wp\/v2\/material_model\/2568","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.jcinjectionmolding.com\/vi\/wp-json\/wp\/v2\/material_model"}],"about":[{"href":"https:\/\/www.jcinjectionmolding.com\/vi\/wp-json\/wp\/v2\/types\/material_model"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.jcinjectionmolding.com\/vi\/wp-json\/wp\/v2\/media\/2519"}],"wp:attachment":[{"href":"https:\/\/www.jcinjectionmolding.com\/vi\/wp-json\/wp\/v2\/media?parent=2568"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}