{"id":2353,"date":"2026-05-23T10:13:31","date_gmt":"2026-05-23T02:13:31","guid":{"rendered":"https:\/\/www.jcinjectionmolding.com\/?p=2353"},"modified":"2026-05-29T15:40:04","modified_gmt":"2026-05-29T07:40:04","slug":"pp-exxonmobil-pp1013","status":"publish","type":"material_model","link":"https:\/\/www.jcinjectionmolding.com\/pt\/materials\/polypropylene-pp\/pp-exxonmobil-pp1013\/","title":{"rendered":"PP-ExxonMobil PP1013"},"content":{"rendered":"<div class=\"material-page-wrapper\" style=\"line-height: 1.7 !important; letter-spacing: 0.03em !important; font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, 'Helvetica Neue', Arial, sans-serif !important; color: #333333 !important;\">\n<p><!-- 3. \u6750\u6599\u4e0b\u5c5e\u578b\u53f7\u4ecb\u7ecd\uff08\u8868\u683c\uff09 --><\/p>\n<section class=\"material-grades\">\n<h2 style=\"font-size: 26px !important; color: #111111 !important; margin-top: 35px !important; margin-bottom: 18px !important; font-weight: 600 !important; letter-spacing: 0.04em !important;\">ExxonMobil PP1013H1 Medical &amp; Regulatory Compliance Profile<\/h2>\n<p style=\"margin-bottom: 18px !important; color: #4a4a4a !important;\">ExxonMobil\u2122 PP1013H1 is a highly specialized homopolymer resin certified for demanding medical and pharmaceutical fluid-contact applications:<\/p>\n<table style=\"width: 100% !important; border-collapse: collapse !important; margin-top: 20px !important; margin-bottom: 30px !important; border: 1px solid #cccccc !important;\">\n<thead>\n<tr>\n<th style=\"background-color: #f0f4f8 !important; color: #111111 !important; font-weight: 600 !important; padding: 14px 18px !important; border: 1px solid #cccccc !important; text-align: left !important; letter-spacing: 0.04em !important; line-height: 1.7 !important;\">Regulatory Standard<\/th>\n<th style=\"background-color: #f0f4f8 !important; color: #111111 !important; font-weight: 600 !important; padding: 14px 18px !important; border: 1px solid #cccccc !important; text-align: left !important; letter-spacing: 0.04em !important; line-height: 1.7 !important;\">Certification Reference<\/th>\n<th style=\"background-color: #f0f4f8 !important; color: #111111 !important; font-weight: 600 !important; padding: 14px 18px !important; border: 1px solid #cccccc !important; text-align: left !important; letter-spacing: 0.04em !important; line-height: 1.7 !important;\">Implication for MedTech Assemblies<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"padding: 14px 18px !important; border: 1px solid #cccccc !important; color: #4a4a4a !important; line-height: 1.7 !important; font-weight: bold;\">Biocompatibilidade<\/td>\n<td style=\"padding: 14px 18px !important; border: 1px solid #cccccc !important; color: #4a4a4a !important; line-height: 1.7 !important;\">USP Class VI \/ ISO 10993-5, 10, 11<\/td>\n<td style=\"padding: 14px 18px !important; border: 1px solid #cccccc !important; color: #4a4a4a !important; line-height: 1.7 !important;\">Guarantees zero systemic toxicity, zero skin sensitization, and zero in-vitro cytotoxicity during active fluid delivery.<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 14px 18px !important; border: 1px solid #cccccc !important; color: #4a4a4a !important; line-height: 1.7 !important; font-weight: bold;\">Arquivo mestre farmac\u00eautico<\/td>\n<td style=\"padding: 14px 18px !important; border: 1px solid #cccccc !important; color: #4a4a4a !important; line-height: 1.7 !important;\">US FDA DMF 15657<\/td>\n<td style=\"padding: 14px 18px !important; border: 1px solid #cccccc !important; color: #4a4a4a !important; line-height: 1.7 !important;\">Enables simplified drug master filing and regulatory pathway clearance for medical packaging and pre-filled syringe barrels.<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 14px 18px !important; border: 1px solid #cccccc !important; color: #4a4a4a !important; line-height: 1.7 !important; font-weight: bold;\">Monograph Compliance<\/td>\n<td style=\"padding: 14px 18px !important; border: 1px solid #cccccc !important; color: #4a4a4a !important; line-height: 1.7 !important;\">EP Monograph 3.1.3, 3.1.6, 3.2.2<\/td>\n<td style=\"padding: 14px 18px !important; border: 1px solid #cccccc !important; color: #4a4a4a !important; line-height: 1.7 !important;\">Complies with European Pharmacopoeia standards for plastic materials used for blood containers, tubing, and pharmaceutical closures.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/section>\n<p><!-- 4. \u6750\u6599\u6240\u5e94\u7528\u7684\u5de5\u827a\u4ecb\u7ecd\uff08\u8868\u683c\uff09 --><\/p>\n<section class=\"molding-processes\">\n<h2 style=\"font-size: 26px !important; color: #111111 !important; margin-top: 35px !important; margin-bottom: 18px !important; font-weight: 600 !important; letter-spacing: 0.04em !important;\">Sterilization Adaptability for ExxonMobil PP1013<\/h2>\n<p style=\"margin-bottom: 18px !important; color: #4a4a4a !important;\">Medical devices must withstand intensive sterilization cycles. This grade is optimized to maintain physical integrity across all major sterilization methods:<\/p>\n<table style=\"width: 100% !important; border-collapse: collapse !important; margin-top: 20px !important; margin-bottom: 30px !important; border: 1px solid #cccccc !important;\">\n<thead>\n<tr>\n<th style=\"background-color: #f0f4f8 !important; color: #111111 !important; font-weight: 600 !important; padding: 14px 18px !important; border: 1px solid #cccccc !important; text-align: left !important; letter-spacing: 0.04em !important; line-height: 1.7 !important;\">Sterilization Methodology<\/th>\n<th style=\"background-color: #f0f4f8 !important; color: #111111 !important; font-weight: 600 !important; padding: 14px 18px !important; border: 1px solid #cccccc !important; text-align: left !important; letter-spacing: 0.04em !important; line-height: 1.7 !important;\">Material Tolerance &amp; Structural Integrity<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"padding: 14px 18px !important; border: 1px solid #cccccc !important; color: #4a4a4a !important; line-height: 1.7 !important; font-weight: bold;\">Autoclave &amp; Steam Sterilization<\/td>\n<td style=\"padding: 14px 18px !important; border: 1px solid #cccccc !important; color: #4a4a4a !important; line-height: 1.7 !important;\">Excellent. Withstands standard pressurized steam cycles up to 121\u00b0C\u2013134\u00b0C without mechanical warping or surface degradation.<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 14px 18px !important; border: 1px solid #cccccc !important; color: #4a4a4a !important; line-height: 1.7 !important; font-weight: bold;\">Ethylene Oxide (EtO) Gas<\/td>\n<td style=\"padding: 14px 18px !important; border: 1px solid #cccccc !important; color: #4a4a4a !important; line-height: 1.7 !important;\">Excellent. Highly compatible with EtO chamber sterilization, exhibiting zero gas absorption or yellowing defects.<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 14px 18px !important; border: 1px solid #cccccc !important; color: #4a4a4a !important; line-height: 1.7 !important; font-weight: bold;\">Gamma Radiation<\/td>\n<td style=\"padding: 14px 18px !important; border: 1px solid #cccccc !important; color: #4a4a4a !important; line-height: 1.7 !important;\">Moderate. Suitable for low-dose gamma cycles. For intensive radiation steps, post-molding yellowing is minimized via optimized cooling times.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/section>\n<p><!-- 5. \u5236\u9020\u6280\u672f\u6307\u5357 --><\/p>\n<section class=\"manufacturing-guide\">\n<h2 style=\"font-size: 26px !important; color: #111111 !important; margin-top: 35px !important; margin-bottom: 18px !important; font-weight: 600 !important; letter-spacing: 0.04em !important;\">Scientific Molding Guide for PP-ExxonMobil PP1013<\/h2>\n<p style=\"margin-bottom: 18px !important; color: #4a4a4a !important;\">Molding medical-grade homopolymer PP requires a high level of process control to eliminate microscopic splay, particulates, and shrinkage voids:<\/p>\n<ul style=\"padding-left: 20px !important; margin-bottom: 25px !important;\">\n<li style=\"margin-bottom: 10px !important; color: #4a4a4a !important;\"><strong>Cleanroom particulate control:<\/strong> To comply with ISO 13485 regulations, Jucheng molds this medical resin strictly inside certified ISO Class 7 and Class 8 cleanrooms. Raw materials are moved through positive-pressure enclosed pneumatic conveying systems.<\/li>\n<li style=\"margin-bottom: 10px !important; color: #4a4a4a !important;\"><strong>Sink-Mark and Void Mitigation:<\/strong> Due to PP1013\u2019s semi-crystalline homopolymer structure, parts are prone to volumetric shrinkage voids. We mitigate this by utilizing lower injection speeds combined with extended packing pressure profiles and generous gate sizing (50% to 70% of part wall thickness).<\/li>\n<li style=\"margin-bottom: 10px !important; color: #4a4a4a !important;\"><strong>Gate Cosmetic and Part Integrity:<\/strong> For syringe plungers and inhaler bodies, gate vestige must be kept minimal. We design premium hot-runner systems or highly detailed sub-gates machined on our 5-axis CNCs to secure clean part separation.<\/li>\n<li style=\"margin-bottom: 10px !important; color: #4a4a4a !important;\"><strong>Mold Rust &amp; Contamination Protection:<\/strong> To avoid micro-contamination, we use premium S136 stainless steel hardened to 50 HRC for our molds. This prevents any oxidation from mold sweat or condensation during long runs.<\/li>\n<\/ul>\n<\/section>\n<p><!-- 6. \u4e3b\u8981\u5e94\u7528\u884c\u4e1a\u9886\u57df --><\/p>\n<section class=\"key-applications\">\n<h2 style=\"font-size: 26px !important; color: #111111 !important; margin-top: 35px !important; margin-bottom: 18px !important; font-weight: 600 !important; letter-spacing: 0.04em !important;\">Key Application Fields for PP-ExxonMobil PP1013<\/h2>\n<ul style=\"padding-left: 20px !important; margin-bottom: 25px !important;\">\n<li style=\"margin-bottom: 10px !important; color: #4a4a4a !important;\"><strong>Diagnostics &amp; Labware:<\/strong> Highly transparent test tubes, specimen vials, pipette tips, petri dishes, and PCR multi-well plates.<\/li>\n<li style=\"margin-bottom: 10px !important; color: #4a4a4a !important;\"><strong>Drug Delivery Components:<\/strong> Disposable syringe barrels, pre-filled syringes, inhaler bodies, insulin pen casings, and liquid medicine dispensers.<\/li>\n<li style=\"margin-bottom: 10px !important; color: #4a4a4a !important;\"><strong>Medical Packaging &amp; Closures:<\/strong> Child-resistant pharmaceutical caps, dropper caps, sterile vial closures, and pharmaceutical blister containers.<\/li>\n<\/ul>\n<\/section>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>ExxonMobil PP1013H1 Medical &amp; Regulatory Compliance Profile ExxonMobil\u2122 PP1013H1 is a highly specialized homopolymer resin certified for demanding medical and pharmaceutical fluid-contact applications: Regulatory Standard Certification Reference Implication for MedTech Assemblies Biocompatibility USP Class VI \/ ISO 10993-5, 10, 11 Guarantees zero systemic toxicity, zero skin sensitization, and zero in-vitro cytotoxicity during active fluid delivery. [&hellip;]<\/p>\n","protected":false},"featured_media":2429,"template":"","meta":[],"class_list":["post-2353","material_model","type-material_model","status-publish","has-post-thumbnail","hentry"],"_links":{"self":[{"href":"https:\/\/www.jcinjectionmolding.com\/pt\/wp-json\/wp\/v2\/material_model\/2353","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.jcinjectionmolding.com\/pt\/wp-json\/wp\/v2\/material_model"}],"about":[{"href":"https:\/\/www.jcinjectionmolding.com\/pt\/wp-json\/wp\/v2\/types\/material_model"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.jcinjectionmolding.com\/pt\/wp-json\/wp\/v2\/media\/2429"}],"wp:attachment":[{"href":"https:\/\/www.jcinjectionmolding.com\/pt\/wp-json\/wp\/v2\/media?parent=2353"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}