{"id":2498,"date":"2026-05-30T16:08:43","date_gmt":"2026-05-30T08:08:43","guid":{"rendered":"https:\/\/www.jcinjectionmolding.com\/?p=2498"},"modified":"2026-06-29T16:47:06","modified_gmt":"2026-06-29T08:47:06","slug":"pei-sabic-ultem-hu1000","status":"publish","type":"material_model","link":"https:\/\/www.jcinjectionmolding.com\/ko\/materials\/polyetherimide-pei-ultem\/pei-sabic-ultem-hu1000\/","title":{"rendered":"PEI-SABIC Ultem HU1000"},"content":{"rendered":"<div class=\"material-page-wrapper\" style=\"line-height: 1.7 !important;letter-spacing: 0.03em !important;, Arial, sans-serif !important;color: #333333 !important\">\n<p><!-- 3. \u6750\u6599\u4e0b\u5c5e\u578b\u53f7\u4ecb\u7ecd\uff08\u8868\u683c\uff09 --><\/p>\n<section class=\"material-grades\">\n<h2 style=\"font-size: 26px !important;color: #111111 !important;margin-top: 35px !important;margin-bottom: 18px !important;font-weight: 600 !important;letter-spacing: 0.04em !important\">Ultem HU1000 Medical Biocompatibility &amp; Autoclave Specs<\/h2>\n<p style=\"margin-bottom: 18px !important;color: #4a4a4a !important\">SABIC\u2122 ULTEM\u2122 Resin HU1000 is an unreinforced amorphous Healthcare-grade Polyetherimide (PEI) resin, certified to deliver outstanding biocompatibility and high-heat sterilization resistance under ISO\/ASTM standards:<\/p>\n<table style=\"width: 100% !important;border-collapse: collapse !important;margin-top: 20px !important;margin-bottom: 30px !important;border: 1px solid #9cc2c2 !important\">\n<thead>\n<tr>\n<th style=\"background-color: #e6f2f2 !important;color: #111111 !important;font-weight: 600 !important;padding: 14px 18px !important;border: 1px solid #9cc2c2 !important;text-align: left !important;letter-spacing: 0.04em !important;line-height: 1.7 !important\">Biocompatibility \/ Sterilization Spec<\/th>\n<th style=\"background-color: #e6f2f2 !important;color: #111111 !important;font-weight: 600 !important;padding: 14px 18px !important;border: 1px solid #9cc2c2 !important;text-align: left !important;letter-spacing: 0.04em !important;line-height: 1.7 !important\">SABIC Ultem HU1000 Value<\/th>\n<th style=\"background-color: #e6f2f2 !important;color: #111111 !important;font-weight: 600 !important;padding: 14px 18px !important;border: 1px solid #9cc2c2 !important;text-align: left !important;letter-spacing: 0.04em !important;line-height: 1.7 !important\">MedTech Assembly Benefit<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"padding: 14px 18px !important;border: 1px solid #9cc2c2 !important;color: #4a4a4a !important;line-height: 1.7 !important;font-weight: bold\">Biocompatibility Certification<\/td>\n<td style=\"padding: 14px 18px !important;border: 1px solid #9cc2c2 !important;color: #4a4a4a !important;line-height: 1.7 !important\">ISO 10993 \ubc0f USP Class VI \uc900\uc218<\/td>\n<td style=\"padding: 14px 18px !important;border: 1px solid #9cc2c2 !important;color: #4a4a4a !important;line-height: 1.7 !important\">Guarantees complete non-toxicity and biological safety for short-term human tissue contact and dynamic fluidic pathways.<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 14px 18px !important;border: 1px solid #9cc2c2 !important;color: #4a4a4a !important;line-height: 1.7 !important;font-weight: bold\">\uc624\ud1a0\ud074\ub808\uc774\ube0c \uac00\uc218\ubd84\ud574 \uc218\uba85<\/td>\n<td style=\"padding: 1,000+ autoclave steam cycles limit\">Retains 100% Structural Properties<\/td>\n<td style=\"padding: 14px 18px !important;border: 1px solid #9cc2c2 !important;color: #4a4a4a !important;line-height: 1.7 !important\">Withstands repeated steam-sterilization at 134\u00b0C without cracking, structural warping, or loss of aesthetic transparency.<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 14px 18px !important;border: 1px solid #9cc2c2 !important;color: #4a4a4a !important;line-height: 1.7 !important;font-weight: bold\">Chemical Resistance<\/td>\n<td style=\"padding: 14px 18px !important;border: 1px solid #9cc2c2 !important;color: #4a4a4a !important;line-height: 1.7 !important\">High resistance to clinical lipids &amp; sanitizers<\/td>\n<td style=\"padding: 14px 18px !important;border: 1px solid #9cc2c2 !important;color: #4a4a4a !important;line-height: 1.7 !important\">Resists stress cracking under constant contact with surgical disinfectants, clinical hydrocarbons, and aggressive bodily lipids.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/section>\n<p><!-- 4. \u6750\u6599\u6240\u5e94\u7528\u7684\u5de5\u827a\u4ecb\u7ecd\uff08\u8868\u683c\uff09 --><\/p>\n<section class=\"molding-processes\">\n<h2 style=\"font-size: 26px !important;color: #111111 !important;margin-top: 35px !important;margin-bottom: 18px !important;font-weight: 600 !important;letter-spacing: 0.04em !important\">Clinical Process Configurations for Biocompatible Ultem HU1000<\/h2>\n<p style=\"margin-bottom: 18px !important;color: #4a4a4a !important\">With standard melt viscosity and high thermal stability, SABIC Ultem HU1000 processes reliably inside high-heat medical systems:<\/p>\n<table style=\"width: 100% !important;border-collapse: collapse !important;margin-top: 20px !important;margin-bottom: 30px !important;border: 1px solid #9cc2c2 !important\">\n<thead>\n<tr>\n<th style=\"background-color: #f3f4f6 !important;color: #111111 !important;font-weight: 600 !important;padding: 14px 18px !important;border: 1px solid #9cc2c2 !important;text-align: left !important;letter-spacing: 0.04em !important;line-height: 1.7 !important\">Clinical Application Category<\/th>\n<th style=\"background-color: #f3f4f6 !important;color: #111111 !important;font-weight: 600 !important;padding: 14px 18px !important;border: 1px solid #9cc2c2 !important;text-align: left !important;letter-spacing: 0.04em !important;line-height: 1.7 !important\">\uacf5\uc815 \ud638\ud658\uc131 \ubc0f \uc6b4\uc601 \uc138\ubd80 \uc0ac\ud56d<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"padding: 14px 18px !important;border: 1px solid #9cc2c2 !important;color: #4a4a4a !important;line-height: 1.7 !important;font-weight: bold\">Autoclavable Surgical Trays<\/td>\n<td style=\"padding: 14px 18px !important;border: 1px solid #9cc2c2 !important;color: #4a4a4a !important;line-height: 1.7 !important\">Excellent. Run inside our ISO Class 7\/8 cleanrooms to mold highly complex surgical instrument sterilization trays, cassettes, and brackets.<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 14px 18px !important;border: 1px solid #9cc2c2 !important;color: #4a4a4a !important;line-height: 1.7 !important;font-weight: bold\">High-Viscosity Medical Manifolds<\/td>\n<td style=\"padding: 14px 18px !important;border: 1px solid #9cc2c2 !important;color: #4a4a4a !important;line-height: 1.7 !important\">Excellent. Highly optimized for transparent medicine delivery manifolds, dialyzer housings, pharmaceutical fluidic valves, and diagnostic tubes.<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 14px 18px !important;border: 1px solid #9cc2c2 !important;color: #4a4a4a !important;line-height: 1.7 !important;font-weight: bold\">Diagnostic Device Shells<\/td>\n<td style=\"padding: 14px 18px !important;border: 1px solid #9cc2c2 !important;color: #4a4a4a !important;line-height: 1.7 !important\">Good. Outstanding structural strength and low outgassing enable clean, high-precision housings for surgical optical devices and clinical tools.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/section>\n<p><!-- 5. \u5236\u9020\u6280\u672f\u6307\u5357 --><\/p>\n<section class=\"manufacturing-guide\">\n<h2 style=\"font-size: 26px !important;color: #111111 !important;margin-top: 35px !important;margin-bottom: 18px !important;font-weight: 600 !important;letter-spacing: 0.04em !important\">ISO 13485 Healthcare Molding &amp; Purity Matrix<\/h2>\n<p style=\"margin-bottom: 18px !important;color: #4a4a4a !important\">Molding an amorphous medical-grade resin like Ultem HU1000 requires strict thermal controls and full-contamination prevention protocols:<\/p>\n<div style=\"border: 1px solid #9cc2c2 !important;margin-top: 20px !important;margin-bottom: 20px !important\">\n<div style=\"background-color: #e6f2f2 !important;padding: 18px !important;border-bottom: 1px solid #9cc2c2 !important\">\n<p style=\"margin-bottom: 0px !important;color: #111111 !important;font-weight: bold;font-size: 15px !important\">ISO Class 7\/8 \ud074\ub9b0\ub8f8 \uc0ac\ucd9c \uc131\ud615<\/p>\n<p style=\"margin-top: 8px !important;margin-bottom: 0px !important;color: #4a4a4a !important;font-size: 14px !important\">Medical-grade PEEK and PEI must be protected from any airborne particulates or dust. Jucheng operates dedicated injection molding machines inside fully enclosed, positive-pressure ISO Class 7\/8 cleanrooms. Raw material feeding, plastication, and robot part-ejection are completely automated and isolated.<\/p>\n<\/div>\n<div style=\"background-color: #f3f4f6 !important;padding: 18px !important;border-bottom: 1px solid #9cc2c2 !important\">\n<p style=\"margin-bottom: 0px !important;color: #111111 !important;font-weight: bold;font-size: 15px !important\">\ubbf8\ub7ec \ud3f4\ub9ac\uc2f1 S136 \uae08\ud615 (\uc21c\ub3c4 \ubcf4\uc874)<\/p>\n<p style=\"margin-top: 8px !important;margin-bottom: 0px !important;color: #4a4a4a !important;font-size: 14px !important\">\ubbf8\uc138\ud55c \ud45c\uba74 \ubbf8\uc138 \uac70\uce60\uae30\ub85c \uc778\ud55c \uc870\uc9c1 \uc790\uadf9\uc744 \ubc29\uc9c0\ud558\uae30 \uc704\ud574 \uace0\ud06c\ub86c S136 \uc2a4\ud14c\uc778\ub9ac\uc2a4 \uac15\uc73c\ub85c \uae08\ud615\uc744 \uc81c\uc791\ud569\ub2c8\ub2e4. \uce90\ube44\ud2f0\ub294 \uae68\ub057\ud55c \ub2e4\uc774\uc544\ubaac\ub4dc \ud398\uc774\uc2a4\ud2b8\ub97c \uc0ac\uc6a9\ud558\uc5ec \ub192\uc740 \uc218\uc900\uc73c\ub85c \ubbf8\ub7ec \ud3f4\ub9ac\uc2f1\ub418\uc5b4, \ub3d9\uc801 \uc774\ud615 \ub4dc\ub798\uadf8 \ub9c8\ud06c \uc5c6\uc774 \ubb34\uacf5\uadf9 \uc0dd\uccb4 \uc801\ud569\uc131 \ubd80\ud488 \ud45c\uba74\uc744 \ubcf4\uc7a5\ud569\ub2c8\ub2e4.<\/p>\n<\/div>\n<div style=\"background-color: #e6f2f2 !important;padding: 18px !important;border-bottom: 1px solid #9cc2c2 !important\">\n<p style=\"margin-bottom: 0px !important;color: #111111 !important;font-weight: bold;font-size: 15px !important\">\uac00\uc555 \uc624\uc77c \ubab0\ub4dc \uc628\ub3c4 \ub9e4\ud2b8\ub9ad\uc2a4<\/p>\n<p style=\"margin-top: 8px !important;margin-bottom: 0px !important;color: #4a4a4a !important;font-size: 14px !important\">To minimize internal thermal stresses, mold temperatures are maintained continuously at 140\u00b0C\u2013180\u00b0C (284\u00b0F to 356\u00b0F) using pressurized oil temperature controllers. Cold molds cause high internal stresses, which severely compromises environmental stress-crack resistance (ESCR) under aggressive clinical fluid exposure.<\/p>\n<\/div>\n<div style=\"background-color: #f3f4f6 !important;padding: 18px !important\">\n<p style=\"margin-bottom: 0px !important;color: #111111 !important;font-weight: bold;font-size: 15px !important\">\ud655\uc7a5\ub41c \uac74\uc870\uc81c \uc0ac\uc804 \uac74\uc870 \ud504\ub85c\ud1a0\ucf5c<\/p>\n<p style=\"margin-top: 8px !important;margin-bottom: 0px !important;color: #4a4a4a !important;font-size: 14px !important\">PEI\ub294 \ub9e4\uc6b0 \ud761\uc2b5\uc131\uc785\ub2c8\ub2e4. \uc218\ubd84\uc740 \uc678\uad00\uc0c1\uc758 \uc2a4\ud50c\ub808\uc774, \uae30\ud3ec \ubc0f \ud22c\uba85 \uad11\ud559 \ud488\uc9c8 \uc190\uc2e4\uc744 \uc720\ubc1c\ud569\ub2c8\ub2e4. \uc131\ud615 \uc804\uc5d0 \uc81c\uc2b5 \ud638\ud37c \uac74\uc870\uae30\uc5d0\uc11c 150\u00b0C(302\u00b0F)\ub85c 4\uc2dc\uac04 \ub3d9\uc548 \uc6d0\ub8cc\ub97c \uac74\uc870\ud558\uc5ec \uc218\ubd84 \uc218\uc900\uc744 0.02% \ubbf8\ub9cc\uc73c\ub85c \uc720\uc9c0\ud558\uace0 \ub3d9\uc801 \uae30\uacc4\uc801 \uc778\uc7a5 \uacb0\ud569\uc744 \ubcf4\ud638\ud569\ub2c8\ub2e4.<\/p>\n<\/div>\n<\/div>\n<\/section>\n<p><!-- 6. \u4e3b\u8981\u5e94\u7528\u884c\u4e1a\u9886\u57df --><\/p>\n<section class=\"key-applications\">\n<h2 style=\"font-size: 26px !important;color: #111111 !important;margin-top: 35px !important;margin-bottom: 18px !important;font-weight: 600 !important;letter-spacing: 0.04em !important\">Key Application Fields for PEI-SABIC Ultem HU1000<\/h2>\n<ul style=\"padding-left: 20px !important;margin-bottom: 25px !important\">\n<li style=\"margin-bottom: 10px !important;color: #4a4a4a !important\"><strong>Surgical &amp; Orthopedic Systems:<\/strong> Autoclavable surgical sterilization trays, instrument brackets, dental trial guides, surgical drill guides, and laser diagnostic manifolds.<\/li>\n<li style=\"margin-bottom: 10px !important;color: #4a4a4a !important\"><strong>Clinical Fluid Management:<\/strong> Hemodialysis dialyzer housings, pharmaceutical fluidic valves, IV drip chambers, fluid connectors, and catheter adapters.<\/li>\n<li style=\"margin-bottom: 10px !important;color: #4a4a4a !important\"><strong>Advanced MedTech Enclosures:<\/strong> Surgical optical tool casings, medical monitor bezels, diagnostic device covers, and hospital electrical switch terminals.<\/li>\n<\/ul>\n<\/section>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Ultem HU1000 Medical Biocompatibility &amp; Autoclave Specs SABIC\u2122 ULTEM\u2122 Resin HU1000 is an unreinforced amorphous Healthcare-grade Polyetherimide (PEI) resin, certified to deliver outstanding biocompatibility and high-heat sterilization resistance under ISO\/ASTM standards: Biocompatibility \/ Sterilization Spec SABIC Ultem HU1000 Value MedTech Assembly Benefit Biocompatibility Certification ISO 10993 &amp; USP Class VI Compliant Guarantees complete non-toxicity and [&hellip;]<\/p>\n","protected":false},"featured_media":2499,"template":"","meta":[],"class_list":["post-2498","material_model","type-material_model","status-publish","has-post-thumbnail","hentry"],"_links":{"self":[{"href":"https:\/\/www.jcinjectionmolding.com\/ko\/wp-json\/wp\/v2\/material_model\/2498","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.jcinjectionmolding.com\/ko\/wp-json\/wp\/v2\/material_model"}],"about":[{"href":"https:\/\/www.jcinjectionmolding.com\/ko\/wp-json\/wp\/v2\/types\/material_model"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.jcinjectionmolding.com\/ko\/wp-json\/wp\/v2\/media\/2499"}],"wp:attachment":[{"href":"https:\/\/www.jcinjectionmolding.com\/ko\/wp-json\/wp\/v2\/media?parent=2498"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}