{"id":3333,"date":"2026-09-04T16:56:56","date_gmt":"2026-09-04T08:56:56","guid":{"rendered":"http:\/\/0"},"modified":"2026-09-04T10:14:34","modified_gmt":"2026-09-04T02:14:34","slug":"lsr-materials-choose-grade-by-function","status":"publish","type":"post","link":"https:\/\/www.jcinjectionmolding.com\/ja\/blog\/lsr-materials-choose-grade-by-function\/","title":{"rendered":"\u3069\u306eLSR\u6750\u6599\u304c\u90e8\u54c1\u306e\u5b9f\u969b\u306e\u5f79\u5272\u306b\u9069\u5408\u3059\u308b\u304b\uff1f"},"content":{"rendered":"<p style=\"font-size: 20px;line-height: 2em;text-align: left\">Choosing <strong>LSR Injection Molding Materials<\/strong> is not a matter of selecting the softest, clearest, or most widely used silicone. The grade has to match the part\u2019s job, the substrate it touches, the way it will be cured and sterilized, and the acceptance tests that will prove performance. A material decision made only from a data-sheet headline can create problems later in bonding, compression recovery, color stability, or dimensional control.<\/p>\n<p style=\"font-size: 20px;line-height: 2em;text-align: left\">For a project using <a href=\"https:\/\/www.jcinjectionmolding.com\/ja\/service\/liquid-silicone-rubber-lsr-molding\/\">\u6db2\u72b6\u30b7\u30ea\u30b3\u30fc\u30f3\u30b4\u30e0\uff08LSR\uff09\u6210\u5f62<\/a>, begin by translating the product requirement into measurable material functions. This article organizes the selection around those functions so that the grade, tool, and process can be developed together.<\/p>\n<h2 style=\"font-size: 28px;line-height: 2em\">Start with the part\u2019s job<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3355\" src=\"https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/09\/LSR-functional-sample-set.webp\" alt=\"LSR-functional-sample-set\" width=\"1672\" height=\"941\" srcset=\"https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/09\/LSR-functional-sample-set.webp 1672w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/09\/LSR-functional-sample-set-300x169.webp 300w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/09\/LSR-functional-sample-set-1024x576.webp 1024w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/09\/LSR-functional-sample-set-768x432.webp 768w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/09\/LSR-functional-sample-set-1536x864.webp 1536w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/09\/LSR-functional-sample-set-18x10.webp 18w\" sizes=\"auto, (max-width: 1672px) 100vw, 1672px\" \/><\/p>\n<p style=\"font-size: 20px;line-height: 2em;text-align: left\">A gasket needs stable compression and sealing recovery. A flexible membrane needs controlled deflection and tear resistance. A grip needs tactile feel, abrasion resistance, and a predictable bond to its substrate. A fluid-contact component may need limits for extractables, cleanliness, and sterilization exposure. These are different priorities, even when the parts are all described as silicone.<\/p>\n<table style=\"width: 100%;border-collapse: collapse;font-size: 18px;line-height: 1.8em\">\n<tbody>\n<tr>\n<th style=\"border: 1px solid #ccc;padding: 10px;text-align: left\">Function<\/th>\n<th style=\"border: 1px solid #ccc;padding: 10px;text-align: left\">Material questions<\/th>\n<th style=\"border: 1px solid #ccc;padding: 10px;text-align: left\">Useful validation<\/th>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ccc;padding: 10px\">\u30b7\u30fc\u30eb<\/td>\n<td style=\"border: 1px solid #ccc;padding: 10px\">Hardness, compression set, chemical exposure<\/td>\n<td style=\"border: 1px solid #ccc;padding: 10px\">Leak and compression-recovery testing<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ccc;padding: 10px\">Flex<\/td>\n<td style=\"border: 1px solid #ccc;padding: 10px\">Tear strength, elongation, fatigue behavior<\/td>\n<td style=\"border: 1px solid #ccc;padding: 10px\">Cycle and tensile testing<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ccc;padding: 10px\">Bond<\/td>\n<td style=\"border: 1px solid #ccc;padding: 10px\">Substrate compatibility and cure chemistry<\/td>\n<td style=\"border: 1px solid #ccc;padding: 10px\">Peel, pull, or torsion test<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ccc;padding: 10px\">Appearance<\/td>\n<td style=\"border: 1px solid #ccc;padding: 10px\">Clarity, color stability, surface finish<\/td>\n<td style=\"border: 1px solid #ccc;padding: 10px\">Defined visual standard and aging review<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2 style=\"font-size: 28px;line-height: 2em\">Hardness is a design input, not a product identity<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3359\" src=\"https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/09\/LSR-hardness-comparison-test.webp\" alt=\"LSR-hardness-comparison-test\" width=\"1672\" height=\"941\" srcset=\"https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/09\/LSR-hardness-comparison-test.webp 1672w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/09\/LSR-hardness-comparison-test-300x169.webp 300w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/09\/LSR-hardness-comparison-test-1024x576.webp 1024w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/09\/LSR-hardness-comparison-test-768x432.webp 768w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/09\/LSR-hardness-comparison-test-1536x864.webp 1536w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/09\/LSR-hardness-comparison-test-18x10.webp 18w\" sizes=\"auto, (max-width: 1672px) 100vw, 1672px\" \/><\/p>\n<p style=\"font-size: 20px;line-height: 2em;text-align: left\">Durometer affects how a part seals, flexes, feels, and releases from the mold, but the same nominal hardness can behave differently in different geometries. A thin lip may be compliant even with a relatively firm grade, while a thick pad can feel rigid because of its section. Specify the actual function, compression, deflection, and recovery requirement alongside a hardness range.<\/p>\n<p style=\"font-size: 20px;line-height: 2em;text-align: left\">Check whether the grade\u2019s tensile, elongation, tear, compression-set, and temperature data were generated under conditions relevant to your part. Treat published values as comparison data, not as a promise for every molded geometry. The final part must be tested after the process and any required post-treatment.<\/p>\n<h2 style=\"font-size: 28px;line-height: 2em\">Match cure chemistry to the application and process<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3348\" src=\"https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/09\/LSR-cure-chemistry-control.webp\" alt=\"LSR-cure-chemistry-control\" width=\"1672\" height=\"941\" srcset=\"https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/09\/LSR-cure-chemistry-control.webp 1672w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/09\/LSR-cure-chemistry-control-300x169.webp 300w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/09\/LSR-cure-chemistry-control-1024x576.webp 1024w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/09\/LSR-cure-chemistry-control-768x432.webp 768w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/09\/LSR-cure-chemistry-control-1536x864.webp 1536w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/09\/LSR-cure-chemistry-control-18x10.webp 18w\" sizes=\"auto, (max-width: 1672px) 100vw, 1672px\" \/><\/p>\n<p style=\"font-size: 20px;line-height: 2em;text-align: left\">Platinum-cured LSR is common in demanding applications, but the choice still depends on the product specification. Cure speed, mold temperature, pigment system, inhibition sensitivity, post-cure needs, and storage conditions can affect the process window. Keep components separated until metering and mixing, and document the chosen ratio and handling conditions.<\/p>\n<ol style=\"font-size: 20px;line-height: 2em;padding-left: 2em\">\n<li>Confirm the supplier\u2019s recommended cure and storage conditions.<\/li>\n<li>Review any ingredients or surfaces that may inhibit cure.<\/li>\n<li>Determine whether post-cure changes odor, volatiles, color, or dimensions.<\/li>\n<li>Validate cure state on the finished geometry rather than on a flat sample alone.<\/li>\n<\/ol>\n<h2 style=\"font-size: 28px;line-height: 2em\">Evaluate bonding as a system<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3384\" src=\"https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/09\/LSR-substrate-bond-interface.webp\" alt=\"LSR-substrate-bond-interface\" width=\"1672\" height=\"941\" srcset=\"https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/09\/LSR-substrate-bond-interface.webp 1672w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/09\/LSR-substrate-bond-interface-300x169.webp 300w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/09\/LSR-substrate-bond-interface-1024x576.webp 1024w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/09\/LSR-substrate-bond-interface-768x432.webp 768w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/09\/LSR-substrate-bond-interface-1536x864.webp 1536w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/09\/LSR-substrate-bond-interface-18x10.webp 18w\" sizes=\"auto, (max-width: 1672px) 100vw, 1672px\" \/><\/p>\n<p style=\"font-size: 20px;line-height: 2em;text-align: left\">When silicone is molded onto plastic, metal, glass, or another substrate, material choice is only one part of the bond. Surface energy, cleanliness, texture, geometry, primer use, cure temperature, and time all matter. A chemical bond may be strong under one condition but weak after humidity, heat, sterilization, or repeated flexing. A mechanical key, such as a hole, groove, or undercut, may provide a more robust load path when the design allows it.<\/p>\n<p style=\"font-size: 20px;line-height: 2em;text-align: left\">Ask for bond data on the actual substrate and surface treatment. A supplier\u2019s generic compatibility chart can narrow the options, but it cannot replace testing on the final part. Keep the interface away from flash-prone edges and specify how bond coverage will be inspected.<\/p>\n<h2 style=\"font-size: 28px;line-height: 2em\">Separate medical, optical, and general-purpose requirements<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3358\" src=\"https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/09\/LSR-grade-application-samples.webp\" alt=\"LSR-grade-application-samples\" width=\"1672\" height=\"941\" srcset=\"https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/09\/LSR-grade-application-samples.webp 1672w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/09\/LSR-grade-application-samples-300x169.webp 300w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/09\/LSR-grade-application-samples-1024x576.webp 1024w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/09\/LSR-grade-application-samples-768x432.webp 768w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/09\/LSR-grade-application-samples-1536x864.webp 1536w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/09\/LSR-grade-application-samples-18x10.webp 18w\" sizes=\"auto, (max-width: 1672px) 100vw, 1672px\" \/><\/p>\n<p style=\"font-size: 20px;line-height: 2em;text-align: left\">A material selected for a general industrial seal should not be transferred to a fluid-contact or implant-related design without a new qualification review. Medical use can require controlled documentation and biological evaluation; optical use can require exceptional clarity and low visual distortion; electrical use may emphasize dielectric behavior and flame performance. Use the end-use specification to define which grade family is acceptable.<\/p>\n<p style=\"font-size: 20px;line-height: 2em;text-align: left\">\u306e <a href=\"https:\/\/www.jcinjectionmolding.com\/ja\/about\/quality-control\/\">quality-control framework<\/a> is useful for linking lot identity and test records to the material decision. If the project needs controlled handling, review the <a href=\"https:\/\/www.jcinjectionmolding.com\/ja\/about\/facility\/\">\u751f\u7523\u74b0\u5883<\/a> early so cleanliness and packaging expectations are included in the quote and validation plan.<\/p>\n<h2 style=\"font-size: 28px;line-height: 2em\">Use a short-list and a written down-select<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3364\" src=\"https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/09\/LSR-material-downselect-review.webp\" alt=\"LSR-material-downselect-review\" width=\"1672\" height=\"941\" srcset=\"https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/09\/LSR-material-downselect-review.webp 1672w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/09\/LSR-material-downselect-review-300x169.webp 300w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/09\/LSR-material-downselect-review-1024x576.webp 1024w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/09\/LSR-material-downselect-review-768x432.webp 768w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/09\/LSR-material-downselect-review-1536x864.webp 1536w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/09\/LSR-material-downselect-review-18x10.webp 18w\" sizes=\"auto, (max-width: 1672px) 100vw, 1672px\" \/><\/p>\n<p style=\"font-size: 20px;line-height: 2em;text-align: left\">A practical material review ends with a short-list of two or three candidate grades and a written reason for the selection. Record hardness, cure system, substrate compatibility, expected service environment, post-cure, color or clarity, documentation, and test plan. Then review whether the mold design, gate, venting, and process window support the chosen material.<\/p>\n<p style=\"font-size: 20px;line-height: 2em;text-align: left\">The best LSR grade is the one that meets the functional requirement with a controllable process and an evidence package appropriate to the product. A structured down-select prevents the common mistake of optimizing one property while quietly sacrificing sealing, adhesion, cleanliness, or long-term stability.<\/p>","protected":false},"excerpt":{"rendered":"<p>Choosing LSR Injection Molding Materials is not a matter of selecting the softest, clearest, or most widely used silicone. The grade has to match the part\u2019s job, the substrate it touches, the way it will be cured and sterilized, and the acceptance tests that will prove performance. A material decision made only from a data-sheet headline can create problems later in bonding, compression recovery, color stability, or dimensional control. For a project using Liquid Silicone Rubber (LSR) Molding, begin by translating the product requirement into measurable material functions. This article organizes the selection around those functions so that the grade, tool, and process can be developed together. Start with the [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3365,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-3333","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/www.jcinjectionmolding.com\/ja\/wp-json\/wp\/v2\/posts\/3333","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.jcinjectionmolding.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.jcinjectionmolding.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.jcinjectionmolding.com\/ja\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.jcinjectionmolding.com\/ja\/wp-json\/wp\/v2\/comments?post=3333"}],"version-history":[{"count":0,"href":"https:\/\/www.jcinjectionmolding.com\/ja\/wp-json\/wp\/v2\/posts\/3333\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.jcinjectionmolding.com\/ja\/wp-json\/wp\/v2\/media\/3365"}],"wp:attachment":[{"href":"https:\/\/www.jcinjectionmolding.com\/ja\/wp-json\/wp\/v2\/media?parent=3333"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.jcinjectionmolding.com\/ja\/wp-json\/wp\/v2\/categories?post=3333"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.jcinjectionmolding.com\/ja\/wp-json\/wp\/v2\/tags?post=3333"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}