{"id":2545,"date":"2026-06-15T17:06:29","date_gmt":"2026-06-15T09:06:29","guid":{"rendered":"https:\/\/www.jcinjectionmolding.com\/?p=2545"},"modified":"2026-06-29T18:11:58","modified_gmt":"2026-06-29T10:11:58","slug":"tpe-kraiburg-thermolast-m-tm6med","status":"publish","type":"material_model","link":"https:\/\/www.jcinjectionmolding.com\/it\/materials\/thermoplastic-elastomer-tpe\/tpe-kraiburg-thermolast-m-tm6med\/","title":{"rendered":"TPE-KRAIBURG Thermolast M TM6MED"},"content":{"rendered":"<div class=\"material-page-wrapper\" style=\"line-height: 1.7 !important;letter-spacing: 0.03em !important;, Arial, sans-serif !important;color: #333333 !important\">\n<p><!-- 3. \u6750\u6599\u4e0b\u5c5e\u578b\u53f7\u4ecb\u7ecd\uff08\u8868\u683c\uff09 --><\/p>\n<section class=\"material-grades\">\n<h2 style=\"font-size: 26px !important;color: #111111 !important;margin-top: 35px !important;margin-bottom: 18px !important;font-weight: 600 !important;letter-spacing: 0.04em !important\">THERMOLAST M TM6MED Conformit\u00e0 Medica e Profilo Meccanico<\/h2>\n<p style=\"margin-bottom: 18px !important;color: #4a4a4a !important\">THERMOLAST\u00ae M TM6MED (Serie: MC\/tl) \u00e8 un elastomero medicale premium e traslucido progettato da KRAIBURG TPE, certificato secondo USP Classe VI e ISO 10993 per garantire la massima sicurezza biologica:<\/p>\n<table style=\"width: 100% !important;border-collapse: collapse !important;margin-top: 20px !important;margin-bottom: 30px !important;border: 1px solid #9cc0c5 !important\">\n<thead>\n<tr>\n<th style=\"background-color: #e6f2f5 !important;color: #111111 !important;font-weight: 600 !important;padding: 14px 18px !important;border: 1px solid #9cc0c5 !important;text-align: left !important;letter-spacing: 0.04em !important;line-height: 1.7 !important\">Biocompatibilit\u00e0 e Standard di Qualit\u00e0<\/th>\n<th style=\"background-color: #e6f2f5 !important;color: #111111 !important;font-weight: 600 !important;padding: 14px 18px !important;border: 1px solid #9cc0c5 !important;text-align: left !important;letter-spacing: 0.04em !important;line-height: 1.7 !important\">THERMOLAST M TM6MED Metrico<\/th>\n<th style=\"background-color: #e6f2f5 !important;color: #111111 !important;font-weight: 600 !important;padding: 14px 18px !important;border: 1px solid #9cc0c5 !important;text-align: left !important;letter-spacing: 0.04em !important;line-height: 1.7 !important\">Vantaggio del Sovrastampaggio Medico<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"padding: 14px 18px !important;border: 1px solid #9cc0c5 !important;color: #4a4a4a !important;line-height: 1.7 !important;font-weight: bold\">Biocompatibilit\u00e0<\/td>\n<td style=\"padding: 14px 18px !important;border: 1px solid #9cc0c5 !important;color: #4a4a4a !important;line-height: 1.7 !important\">USP Classe VI \/ ISO 10993-4, 5, 10, 11<\/td>\n<td style=\"padding: 14px 18px !important;border: 1px solid #9cc0c5 !important;color: #4a4a4a !important;line-height: 1.7 !important\">Garantisce la completa non tossicit\u00e0 (citotossicit\u00e0, irritazione, emolisi) per il contatto a breve termine con tessuti umani e percorsi fluidici dinamici.<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 14px 18px !important;border: 1px solid #9cc0c5 !important;color: #4a4a4a !important;line-height: 1.7 !important;font-weight: bold\">Adattabilit\u00e0 alla sterilizzazione<\/td>\n<td style=\"padding: 14px 18px !important;border: 1px solid #9cc0c5 !important;color: #4a4a4a !important;line-height: 1.7 !important\">Resistente ad Autoclave 134\u00b0C, EtO e Raggi Gamma<\/td>\n<td style=\"padding: 14px 18px !important;border: 1px solid #9cc0c5 !important;color: #4a4a4a !important;line-height: 1.7 !important\">Resiste a ripetute sterilizzazioni a vapore senza che le propriet\u00e0 dinamiche cambino, evitando perdite o degrado superficiale appiccicoso.<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 14px 18px !important;border: 1px solid #9cc0c5 !important;color: #4a4a4a !important;line-height: 1.7 !important;font-weight: bold\">Formulazione a Base Pura<\/td>\n<td style=\"padding: 14px 18px !important;border: 1px solid #9cc0c5 !important;color: #4a4a4a !important;line-height: 1.7 !important\">Senza Lattice, PVC e Ftalati<\/td>\n<td style=\"padding: 14px 18px !important;border: 1px solid #9cc0c5 !important;color: #4a4a4a !important;line-height: 1.7 !important\">Prodotto in una linea medica dedicata, garantendo un degassamento ultra-basso e zero rischio di rilascio di sostanze estraibili tossiche.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/section>\n<p><!-- 4. \u6750\u6599\u6240\u5e94\u7528\u7684\u5de5\u827a\u4ecb\u7ecd\uff08\u8868\u683c\uff09 --><\/p>\n<section class=\"molding-processes\">\n<h2 style=\"font-size: 26px !important;color: #111111 !important;margin-top: 35px !important;margin-bottom: 18px !important;font-weight: 600 !important;letter-spacing: 0.04em !important\">Configurazioni Cliniche e di Processo per Fluidi per TM6MED Biocompatibile<\/h2>\n<p style=\"margin-bottom: 18px !important;color: #4a4a4a !important\">Grazie al suo elevato allungamento elastico e alla standard adesione chimica, TM6MED \u00e8 altamente adatto per guarnizioni dinamiche pulite:<\/p>\n<table style=\"width: 100% !important;border-collapse: collapse !important;margin-top: 20px !important;margin-bottom: 30px !important;border: 1px solid #9cc0c5 !important\">\n<thead>\n<tr>\n<th style=\"background-color: #faf8f5 !important;color: #111111 !important;font-weight: 600 !important;padding: 14px 18px !important;border: 1px solid #9cc0c5 !important;text-align: left !important;letter-spacing: 0.04em !important;line-height: 1.7 !important\">Categoria di processo<\/th>\n<th style=\"background-color: #faf8f5 !important;color: #111111 !important;font-weight: 600 !important;padding: 14px 18px !important;border: 1px solid #9cc0c5 !important;text-align: left !important;letter-spacing: 0.04em !important;line-height: 1.7 !important\">Compatibilit\u00e0 di stampaggio e dettagli operativi<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"padding: 14px 18px !important;border: 1px solid #9cc0c5 !important;color: #4a4a4a !important;line-height: 1.7 !important;font-weight: bold\">Punte di Stantuffo per Siringhe Dinamiche<\/td>\n<td style=\"padding: 14px 18px !important;border: 1px solid #9cc0c5 !important;color: #4a4a4a !important;line-height: 1.7 !important\">Eccellente. Stampato nelle nostre camere bianche ISO Classe 7\/8 per produrre guarnizioni scorrevoli ad alta purezza, tenute e punte di stantuffo per siringhe con compression set ottimizzato.<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 14px 18px !important;border: 1px solid #9cc0c5 !important;color: #4a4a4a !important;line-height: 1.7 !important;font-weight: bold\">Connettori Flessibili per Pompe Peristaltiche<\/td>\n<td style=\"padding: 14px 18px !important;border: 1px solid #9cc0c5 !important;color: #4a4a4a !important;line-height: 1.7 !important\">Eccellente. Bassi coefficienti di attrito e caratteristiche standard di facile rilascio consentono l'espulsione automatica ad alta efficienza di valvole flessibili e boccagli.<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 14px 18px !important;border: 1px solid #9cc0c5 !important;color: #4a4a4a !important;line-height: 1.7 !important;font-weight: bold\">Impugnature mediche Soft-Touch<\/td>\n<td style=\"padding: 14px 18px !important;border: 1px solid #9cc0c5 !important;color: #4a4a4a !important;line-height: 1.7 !important\">Buono. Eccellente adesione a substrati PP e PE. Ideale per sovrastampaggio su strumenti chirurgici medici rigidi e maniglie di dispositivi diagnostici.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/section>\n<p><!-- 5. \u5236\u9020\u6280\u672f\u6307\u5357 --><\/p>\n<section class=\"manufacturing-guide\">\n<h2 style=\"font-size: 26px !important;color: #111111 !important;margin-top: 35px !important;margin-bottom: 18px !important;font-weight: 600 !important;letter-spacing: 0.04em !important\">Guida alla Stampaggio e Sovrastampaggio TPE-KRAIBURG Thermolast M TM6MED<\/h2>\n<p style=\"margin-bottom: 18px !important;color: #4a4a4a !important\">Lo stampaggio di un elastomero medicale amorfo come TM6MED richiede un controllo rigoroso delle linee di divisione per prevenire bave, insieme al controllo della contaminazione in camera bianca:<\/p>\n<div style=\"border: 1px solid #9cc0c5 !important;margin-top: 20px !important;margin-bottom: 20px !important\">\n<div style=\"background-color: #e6f2f5 !important;padding: 18px !important;border-bottom: 1px solid #9cc0c5 !important\">\n<p style=\"margin-bottom: 0px !important;color: #111111 !important;font-weight: bold;font-size: 15px !important\">Stampaggio a Iniezione in Camera Bianca ISO Classe 7\/8<\/p>\n<p style=\"margin-top: 8px !important;margin-bottom: 0px !important;color: #4a4a4a !important;font-size: 14px !important\">Le resine di grado medicale devono essere protette da qualsiasi particolato o polvere presente nell'aria. Jucheng opera macchine per stampaggio a iniezione dedicate all'interno di camere bianche ISO Classe 7\/8 completamente chiuse e a pressione positiva. L'alimentazione della materia prima, la plastificazione e l'espulsione robotizzata dei pezzi sono completamente automatizzate e isolate.<\/p>\n<\/div>\n<div style=\"background-color: #faf8f5 !important;padding: 18px !important;border-bottom: 1px solid #9cc0c5 !important\">\n<p style=\"margin-bottom: 0px !important;color: #111111 !important;font-weight: bold;font-size: 15px !important\">Utensileria S136 lucidata a specchio (preservazione della purezza)<\/p>\n<p style=\"margin-top: 8px !important;margin-bottom: 0px !important;color: #4a4a4a !important;font-size: 14px !important\">Per prevenire l'irritazione dei tessuti dovuta alla micro-rugosit\u00e0 superficiale, costruiamo stampi utilizzando acciaio inossidabile S136 ad alto contenuto di cromo. Le cavit\u00e0 sono lucidate a specchio ad alto livello utilizzando pasta diamantata pulita, garantendo superfici biocompatibili non porose senza segni di trascinamento dinamico.<\/p>\n<\/div>\n<div style=\"background-color: #e6f2f5 !important;padding: 18px !important;border-bottom: 1px solid #9cc0c5 !important\">\n<p style=\"margin-bottom: 0px !important;color: #111111 !important;font-weight: bold;font-size: 15px !important\">Controllo della temperatura dello stampo a freddo<\/p>\n<p style=\"margin-top: 8px !important;margin-bottom: 0px !important;color: #4a4a4a !important;font-size: 14px !important\">Manteniamo le temperature dello stampo a 20\u00b0C\u201340\u00b0C (68\u00b0F\u2013104\u00b0F) utilizzando refrigeratori ad acqua pressurizzata. Mantenere gli stampi freddi \u00e8 fondamentale per congelare rapidamente la fase elastomerica morbida, consentendo un'espulsione automatica senza deformazioni. Le temperature di fusione sono controllate a 180\u00b0C\u2013220\u00b0C (356\u00b0F\u2013428\u00b0F).<\/p>\n<\/div>\n<div style=\"background-color: #faf8f5 !important;padding: 18px !important\">\n<p style=\"margin-bottom: 0px !important;color: #111111 !important;font-weight: bold;font-size: 15px !important\">Controllo del flash a livello di micron (taglio a bassa viscosit\u00e0)<\/p>\n<p style=\"margin-top: 8px !important;margin-bottom: 0px !important;color: #4a4a4a !important;font-size: 14px !important\">A temperature di fusione di 180\u00b0C\u2013220\u00b0C, il TPE morbido pu\u00f2 facilmente penetrare nei giochi della linea di divisione dello stampo. La divisione utensili di Jucheng utilizza macchine CNC a 5 assi per ottenere micro-tolleranze, mantenendo i giochi di divisione dello stampo strettamente entro 0,005 mm su blocchi di cavit\u00e0 in acciaio inossidabile S136 di qualit\u00e0 superiore.<\/p>\n<\/div>\n<\/div>\n<\/section>\n<p><!-- 6. \u4e3b\u8981\u5e94\u7528\u884c\u4e1a\u9886\u57df --><\/p>\n<section class=\"key-applications\">\n<h2 style=\"font-size: 26px !important;color: #111111 !important;margin-top: 35px !important;margin-bottom: 18px !important;font-weight: 600 !important;letter-spacing: 0.04em !important\">Campi di applicazione chiave per TPE-KRAIBURG Thermolast M TM6MED<\/h2>\n<ul style=\"padding-left: 20px !important;margin-bottom: 25px !important\">\n<li style=\"margin-bottom: 10px !important;color: #4a4a4a !important\"><strong>Dispositivi Medici e Dentali (Certificati ISO 13485):<\/strong> Punte di stantuffo per siringhe mediche dinamiche ad alta precisione, valvole dinamiche per fluidi, connettori flessibili per pompe peristaltiche, impugnature soft-touch e boccagli.<\/li>\n<li style=\"margin-bottom: 10px !important;color: #4a4a4a !important\"><strong>Imballaggi farmaceutici e guarnizioni:<\/strong> Chiusure per flaconi ad alta purezza, tappi per infusione, guarnizioni elastiche di tenuta, membrane dinamiche di dosaggio e guarnizioni per siringhe per somministrazione di farmaci.<\/li>\n<li style=\"margin-bottom: 10px !important;color: #4a4a4a !important\"><strong>Dispositivi di protezione individuale (DPI):<\/strong> Maschere respiratorie flessibili, guarnizioni per occhiali protettivi, strisce di tenuta per visiere e manicotti auricolari dinamici soft-touch.<\/li>\n<\/ul>\n<\/section>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>THERMOLAST M TM6MED Medical Compliance &amp; Mechanical Profile THERMOLAST\u00ae M TM6MED (Series: MC\/tl) is a premium, translucent medical-grade elastomer engineered by KRAIBURG TPE, certified under USP Class VI and ISO 10993 to ensure ultimate biological safety: Biocompatibility &amp; Quality Standard THERMOLAST M TM6MED Metric Medical Overmolding Advantage Biocompatibility USP Class VI \/ ISO 10993-4, 5, [&hellip;]<\/p>\n","protected":false},"featured_media":2510,"template":"","meta":[],"class_list":["post-2545","material_model","type-material_model","status-publish","has-post-thumbnail","hentry"],"_links":{"self":[{"href":"https:\/\/www.jcinjectionmolding.com\/it\/wp-json\/wp\/v2\/material_model\/2545","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.jcinjectionmolding.com\/it\/wp-json\/wp\/v2\/material_model"}],"about":[{"href":"https:\/\/www.jcinjectionmolding.com\/it\/wp-json\/wp\/v2\/types\/material_model"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.jcinjectionmolding.com\/it\/wp-json\/wp\/v2\/media\/2510"}],"wp:attachment":[{"href":"https:\/\/www.jcinjectionmolding.com\/it\/wp-json\/wp\/v2\/media?parent=2545"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}