{"id":2538,"date":"2026-06-15T16:33:45","date_gmt":"2026-06-15T08:33:45","guid":{"rendered":"https:\/\/www.jcinjectionmolding.com\/?p=2538"},"modified":"2026-06-29T17:30:51","modified_gmt":"2026-06-29T09:30:51","slug":"psu-solvay-udel-p-1700","status":"publish","type":"material_model","link":"https:\/\/www.jcinjectionmolding.com\/it\/materials\/psu-ppsu-polysulfone\/psu-solvay-udel-p-1700\/","title":{"rendered":"PSU-Solvay Udel P-1700"},"content":{"rendered":"<div class=\"material-page-wrapper\" style=\"line-height: 1.7 !important;letter-spacing: 0.03em !important;, Arial, sans-serif !important;color: #333333 !important\">\n<p><!-- 3. \u6750\u6599\u4e0b\u5c5e\u578b\u53f7\u4ecb\u7ecd\uff08\u8868\u683c\uff09 --><\/p>\n<section class=\"material-grades\">\n<h2 style=\"font-size: 26px !important;color: #111111 !important;margin-top: 35px !important;margin-bottom: 18px !important;font-weight: 600 !important;letter-spacing: 0.04em !important\">Profilo di conformit\u00e0 fisica e normativa Udel P-1700<\/h2>\n<p style=\"margin-bottom: 18px !important;color: #4a4a4a !important\">Udel\u00ae P-1700 \u00e8 una resina di polisulfone (PSU) amorfa non rinforzata a viscosit\u00e0 standard, certificata per garantire resistenza eccezionale, stabilit\u00e0 idrolitica continua e conformit\u00e0 per alimenti\/acqua potabile:<\/p>\n<table style=\"width: 100% !important;border-collapse: collapse !important;margin-top: 20px !important;margin-bottom: 30px !important;border: 1px solid #a0b5b8 !important\">\n<thead>\n<tr>\n<th style=\"background-color: #edf4f9 !important;color: #111111 !important;font-weight: 600 !important;padding: 14px 18px !important;border: 1px solid #a0b5b8 !important;text-align: left !important;letter-spacing: 0.04em !important;line-height: 1.7 !important\">Standard normativo e di qualit\u00e0<\/th>\n<th style=\"background-color: #edf4f9 !important;color: #111111 !important;font-weight: 600 !important;padding: 14px 18px !important;border: 1px solid #a0b5b8 !important;text-align: left !important;letter-spacing: 0.04em !important;line-height: 1.7 !important\">Riferimento di certificazione Udel P-1700<\/th>\n<th style=\"background-color: #edf4f9 !important;color: #111111 !important;font-weight: 600 !important;padding: 14px 18px !important;border: 1px solid #a0b5b8 !important;text-align: left !important;letter-spacing: 0.04em !important;line-height: 1.7 !important\">Implicazione per MedTech e sistemi idrici<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"padding: 14px 18px !important;border: 1px solid #a0b5b8 !important;color: #4a4a4a !important;line-height: 1.7 !important;font-weight: bold\">Sicurezza dell'acqua potabile<\/td>\n<td style=\"padding: 14px 18px !important;border: 1px solid #a0b5b8 !important;color: #4a4a4a !important;line-height: 1.7 !important\">Elencato NSF STD-61 (commerciale caldo)<\/td>\n<td style=\"padding: 14px 18px !important;border: 1px solid #a0b5b8 !important;color: #4a4a4a !important;line-height: 1.7 !important\">Garantisce la piena sicurezza del materiale per il contatto continuo con acqua calda (testato fino a 82\u00b0C\/180\u00b0F), perfetto per collettori e raccordi idraulici.<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 14px 18px !important;border: 1px solid #a0b5b8 !important;color: #4a4a4a !important;line-height: 1.7 !important;font-weight: bold\">Conformit\u00e0 alla sicurezza alimentare<\/td>\n<td style=\"padding: 14px 18px !important;border: 1px solid #a0b5b8 !important;color: #4a4a4a !important;line-height: 1.7 !important\">FDA 21 CFR 177.1655 \/ NSF STD-51<\/td>\n<td style=\"padding: 14px 18px !important;border: 1px solid #a0b5b8 !important;color: #4a4a4a !important;line-height: 1.7 !important\">Completamente approvato per applicazioni ripetute di contatto diretto con alimenti, garantendo zero odore di plastica o rilascio di sapore sotto calore a vapore a microonde.<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 14px 18px !important;border: 1px solid #a0b5b8 !important;color: #4a4a4a !important;line-height: 1.7 !important;font-weight: bold\">Biocompatibilit\u00e0<\/td>\n<td style=\"padding: 14px 18px !important;border: 1px solid #a0b5b8 !important;color: #4a4a4a !important;line-height: 1.7 !important\">Conforme a ISO 10993 \/ ASTM F702<\/td>\n<td style=\"padding: 14px 18px !important;border: 1px solid #a0b5b8 !important;color: #4a4a4a !important;line-height: 1.7 !important\">Soddisfa gli standard non tossici e bio-inerti per dispositivi medici e componenti a contatto con sangue o fluidi biologici fino a 24 ore.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/section>\n<p><!-- 4. \u6750\u6599\u6240\u5e94\u7528\u7684\u5de5\u827a\u4ecb\u7ecd\uff08\u8868\u683c\uff09 --><\/p>\n<section class=\"molding-processes\">\n<h2 style=\"font-size: 26px !important;color: #111111 !important;margin-top: 35px !important;margin-bottom: 18px !important;font-weight: 600 !important;letter-spacing: 0.04em !important\">Configurazioni di processo e sterilizzazione per Udel P-1700 trasparente<\/h2>\n<p style=\"margin-bottom: 18px !important;color: #4a4a4a !important\">Con la sua struttura amorfa e l'eccellente resistenza del fuso, Udel P-1700 \u00e8 altamente adatto per produzioni stabili di componenti:<\/p>\n<table style=\"width: 100% !important;border-collapse: collapse !important;margin-top: 20px !important;margin-bottom: 30px !important;border: 1px solid #a0b5b8 !important\">\n<thead>\n<tr>\n<th style=\"background-color: #faf5f6 !important;color: #111111 !important;font-weight: 600 !important;padding: 14px 18px !important;border: 1px solid #a0b5b8 !important;text-align: left !important;letter-spacing: 0.04em !important;line-height: 1.7 !important\">Categoria di processo<\/th>\n<th style=\"background-color: #faf5f6 !important;color: #111111 !important;font-weight: 600 !important;padding: 14px 18px !important;border: 1px solid #a0b5b8 !important;text-align: left !important;letter-spacing: 0.04em !important;line-height: 1.7 !important\">Dettagli di compatibilit\u00e0 di stampaggio e impostazione del processo<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"padding: 14px 18px !important;border: 1px solid #a0b5b8 !important;color: #4a4a4a !important;line-height: 1.7 !important;font-weight: bold\">Dispositivi medici autoclavabili<\/td>\n<td style=\"padding: 14px 18px !important;border: 1px solid #a0b5b8 !important;color: #4a4a4a !important;line-height: 1.7 !important\">Eccellente. Stampato nelle nostre camere bianche ISO Classe 7\/8 per produrre collettori fluidici medici, dializzatori per sangue, strumenti chirurgici e componenti dentali.<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 14px 18px !important;border: 1px solid #a0b5b8 !important;color: #4a4a4a !important;line-height: 1.7 !important;font-weight: bold\">Servizio Alimentare e Pentole<\/td>\n<td style=\"padding: 14px 18px !important;border: 1px solid #a0b5b8 !important;color: #4a4a4a !important;line-height: 1.7 !important\">Eccellente. Resiste al riscaldamento a vapore ripetuto a microonde e ai detergenti alcalini aggressivi. Ideale per contenitori alimentari commerciali e attrezzature per latticini.<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 14px 18px !important;border: 1px solid #a0b5b8 !important;color: #4a4a4a !important;line-height: 1.7 !important;font-weight: bold\">Raccordi per Acqua Calda Sanitaria<\/td>\n<td style=\"padding: 14px 18px !important;border: 1px solid #a0b5b8 !important;color: #4a4a4a !important;line-height: 1.7 !important\">Eccellente. Elevata resistenza agli acidi minerali e alle soluzioni saline. Specificato per giunti di tubi per acqua calda residenziali, nuclei di valvole per rubinetti e giunti di collettori.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/section>\n<p><!-- 5. \u5236\u9020\u6280\u672f\u6307\u5357 --><\/p>\n<section class=\"manufacturing-guide\">\n<h2 style=\"font-size: 26px !important;color: #111111 !important;margin-top: 35px !important;margin-bottom: 18px !important;font-weight: 600 !important;letter-spacing: 0.04em !important\">PSU-Solvay Udel P-1700 Stampaggio e Progetto di Degassaggio dell'Umidit\u00e0<\/h2>\n<p style=\"margin-bottom: 18px !important;color: #4a4a4a !important\">Lo stampaggio di una resina amorfa ad alta viscosit\u00e0 come Udel P-1700 richiede un dimensionamento preciso del punto di iniezione per prevenire elevate pressioni di fusione, insieme a un'accurata pre-essiccazione:<\/p>\n<div style=\"border: 1px solid #a0b5b8 !important;margin-top: 20px !important;margin-bottom: 20px !important\">\n<div style=\"background-color: #edf4f9 !important;padding: 18px !important;border-bottom: 1px solid #a0b5b8 !important\">\n<p style=\"margin-bottom: 0px !important;color: #111111 !important;font-weight: bold;font-size: 15px !important\">Essiccazione con Setaccio e Prevenzione dei Difetti Superficiali<\/p>\n<p style=\"margin-top: 8px !important;margin-bottom: 0px !important;color: #4a4a4a !important;font-size: 14px !important\">Il polisulfone \u00e8 altamente igroscopico. L'umidit\u00e0 causa difetti superficiali, bolle e perdita della qualit\u00e0 ottica trasparente. Pre-essicchiamo la resina grezza in essiccatori a tramoggia con setaccio a 135\u00b0C\u2013163\u00b0C (275\u00b0F a 325\u00b0F) per 3,5 ore, mantenendo l'umidit\u00e0 rigorosamente al di sotto dello 0,05% per garantire una densit\u00e0 strutturale ottimale.<\/p>\n<\/div>\n<div style=\"background-color: #faf5f6 !important;padding: 18px !important;border-bottom: 1px solid #a0b5b8 !important\">\n<p style=\"margin-bottom: 0px !important;color: #111111 !important;font-weight: bold;font-size: 15px !important\">Basso Ritiro Isotropico e Stabilit\u00e0 Dimensionale<\/p>\n<p style=\"margin-top: 8px !important;margin-bottom: 0px !important;color: #4a4a4a !important;font-size: 14px !important\">Udel P-1700 presenta un ritiro basso e altamente uniforme (tipicamente 0,70%) grazie alla sua matrice amorfa. Lavoriamo blocchi di cavit\u00e0 e nucleo precisi sulle nostre fresatrici CNC a 5 assi, assicurando che le parti stampate siano completamente piatte e senza deformazioni.<\/p>\n<\/div>\n<div style=\"background-color: #edf4f9 !important;padding: 18px !important;border-bottom: 1px solid #a0b5b8 !important\">\n<p style=\"margin-bottom: 0px !important;color: #111111 !important;font-weight: bold;font-size: 15px !important\">Controllo della Fusione ad Alta Temperatura e dello Stampo<\/p>\n<p style=\"margin-top: 8px !important;margin-bottom: 0px !important;color: #4a4a4a !important;font-size: 14px !important\">Le temperature del cilindro di lavorazione sono mantenute tra 329\u00b0C e 385\u00b0C (625\u00b0F a 725\u00b0F) per garantire un flusso omogeneo. Le temperature dello stampo sono mantenute a 121\u00b0C - 163\u00b0C (250\u00b0F a 325\u00b0F) utilizzando controllori di temperatura a olio pressurizzato per ridurre le tensioni interne di stampaggio.<\/p>\n<\/div>\n<div style=\"background-color: #faf5f6 !important;padding: 18px !important\">\n<p style=\"margin-bottom: 0px !important;color: #111111 !important;font-weight: bold;font-size: 15px !important\">Acciaio per Utensili Resistente alla Ruggine (acciaio S136)<\/p>\n<p style=\"margin-top: 8px !important;margin-bottom: 0px !important;color: #4a4a4a !important;font-size: 14px !important\">Per prevenire la ruggine dello stampo e garantire finiture delle parti di grado ottico, costruiamo le cavit\u00e0 dello stampo in acciaio inossidabile S136 di prima qualit\u00e0, lucidato a specchio ad alto livello. Questo assicura che le parti stampate si stacchino pulite senza segni di trascinamento durante le lavorazioni automatiche.<\/p>\n<\/div>\n<\/div>\n<\/section>\n<p><!-- 6. \u4e3b\u8981\u5e94\u7528\u884c\u4e1a\u9886\u57df --><\/p>\n<section class=\"key-applications\">\n<h2 style=\"font-size: 26px !important;color: #111111 !important;margin-top: 35px !important;margin-bottom: 18px !important;font-weight: 600 !important;letter-spacing: 0.04em !important\">Campi di applicazione chiave per PSU-Solvay Udel P-1700<\/h2>\n<ul style=\"padding-left: 20px !important;margin-bottom: 25px !important\">\n<li style=\"margin-bottom: 10px !important;color: #4a4a4a !important\"><strong>Dispositivi medici e di laboratorio (ISO 13485):<\/strong> Involucri trasparenti per emodializzatori, dispositivi di filtrazione farmaceutica, strumenti chirurgici monouso, parti di strumenti dentali e tazze per test chimici.<\/li>\n<li style=\"margin-bottom: 10px !important;color: #4a4a4a !important\"><strong>Impianti idraulici municipali e industriali:<\/strong> Raccordi per tubi di acqua calda, nuclei di valvole miscelatrici per rubinetti residenziali, collettori dinamici, misuratori di portata e ugelli per irrigazione agricola.<\/li>\n<li style=\"margin-bottom: 10px !important;color: #4a4a4a !important\"><strong>Elettrodomestici commerciali a contatto con alimenti:<\/strong> Biberon autoclavabili, stoviglie per microonde, teglie a vapore per servizio alimentare, attrezzature per latticini commerciali e connettori per macchine per bevande calde.<\/li>\n<\/ul>\n<\/section>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Udel P-1700 Physical &amp; Regulatory Compliance Profile Udel\u00ae P-1700 is an unreinforced, standard-viscosity amorphous Polysulfone (PSU) resin, certified to deliver outstanding strength, continuous hydrolytic stability, and food\/potable water compliance: Regulatory &amp; Quality Standard Udel P-1700 Certification Reference Implication for MedTech &amp; Water Systems Drinking Water Safety NSF STD-61 Listed (Commercial Hot) Guarantees full material safety [&hellip;]<\/p>\n","protected":false},"featured_media":2504,"template":"","meta":[],"class_list":["post-2538","material_model","type-material_model","status-publish","has-post-thumbnail","hentry"],"_links":{"self":[{"href":"https:\/\/www.jcinjectionmolding.com\/it\/wp-json\/wp\/v2\/material_model\/2538","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.jcinjectionmolding.com\/it\/wp-json\/wp\/v2\/material_model"}],"about":[{"href":"https:\/\/www.jcinjectionmolding.com\/it\/wp-json\/wp\/v2\/types\/material_model"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.jcinjectionmolding.com\/it\/wp-json\/wp\/v2\/media\/2504"}],"wp:attachment":[{"href":"https:\/\/www.jcinjectionmolding.com\/it\/wp-json\/wp\/v2\/media?parent=2538"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}