{"id":2786,"date":"2026-08-01T16:28:27","date_gmt":"2026-08-01T08:28:27","guid":{"rendered":"http:\/\/0"},"modified":"2026-07-29T17:42:53","modified_gmt":"2026-07-29T09:42:53","slug":"specs-for-optical-clear-plastic-molding-lens-clarity","status":"publish","type":"post","link":"https:\/\/www.jcinjectionmolding.com\/fr\/blog\/specs-for-optical-clear-plastic-molding-lens-clarity\/","title":{"rendered":"Sp\u00e9cifications pour le moulage de plastique transparent optique : clart\u00e9 des lentilles"},"content":{"rendered":"<article style=\"font-family: -apple-system, BlinkMacSystemFont, &#039;Segoe UI&#039;, Roboto, Helvetica, Arial, sans-serif;color: #333333;width: 100%\">\n<section style=\"margin-bottom: 30px\">\n<p style=\"font-size: 18px;line-height: 1.8em;text-align: left;margin-bottom: 24px\">La transmission impeccable de la lumi\u00e8re dans les lentilles optiques, les guides de lumi\u00e8re et les capots de capteurs exige un contr\u00f4le strict de la puret\u00e9 du polym\u00e8re et de la thermique de moulage. Les particules de poussi\u00e8re microscopiques en suspension, les marques de flux en surface ou la bir\u00e9fringence induite par les contraintes internes provoquent une diffusion de la lumi\u00e8re et une distorsion optique. La fabrication de composants polym\u00e8res \u00e0 haute transmittance repose sur un traitement en salle blanche, des aciers de cavit\u00e9 de moule hautement polis et un profilage pr\u00e9cis de la temp\u00e9rature de fusion. JUCHENG exploite des cellules de fabrication sp\u00e9cialis\u00e9es \u00e0 particules contr\u00f4l\u00e9es, produisant des optiques en plastique haute clart\u00e9 strictement conformes aux dessins techniques des clients.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-2789\" src=\"https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/cleanroom-optical-molding-station.webp\" alt=\"cleanroom-optical-molding-station\" width=\"1376\" height=\"768\" srcset=\"https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/cleanroom-optical-molding-station.webp 1376w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/cleanroom-optical-molding-station-300x167.webp 300w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/cleanroom-optical-molding-station-1024x572.webp 1024w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/cleanroom-optical-molding-station-768x429.webp 768w\" sizes=\"auto, (max-width: 1376px) 100vw, 1376px\" \/><\/p>\n<\/section>\n<p><!-- Table of Contents --><\/p>\n<section style=\"background-color: #f8f9fa;border-left: 4px solid #0056b3;padding: 24px;border-radius: 6px;margin: 40px 0\">\n<h3 style=\"font-size: 22px;font-weight: bold;line-height: 1.5em;margin-top: 0;margin-bottom: 16px;color: #111111\">Table des mati\u00e8res<\/h3>\n<ul style=\"list-style-type: none;padding-left: 0;margin: 0\">\n<li style=\"margin-bottom: 12px\"><a style=\"color: #0056b3;text-decoration: none;font-size: 17px;font-weight: 500\" href=\"#birefringence-control\">1. Contr\u00f4le de la bir\u00e9fringence et r\u00e9duction des contraintes r\u00e9siduelles dans le PMMA\/PC<\/a><\/li>\n<li style=\"margin-bottom: 12px\"><a style=\"color: #0056b3;text-decoration: none;font-size: 17px;font-weight: 500\" href=\"#optical-polymers\">2. R\u00e9sines polym\u00e8res \u00e0 haute transmittance (PMMA, PC optique, COC, COP)<\/a><\/li>\n<li style=\"margin-bottom: 12px\"><a style=\"color: #0056b3;text-decoration: none;font-size: 17px;font-weight: 500\" href=\"#mirror-polish\">3. Poli miroir SPI A-1 et moules en acier inoxydable tremp\u00e9 S136<\/a><\/li>\n<li style=\"margin-bottom: 0\"><a style=\"color: #0056b3;text-decoration: none;font-size: 17px;font-weight: 500\" href=\"#cleanroom-dust-control\">4. Environnement de salle blanche pour \u00e9liminer la poussi\u00e8re et les points noirs<\/a><\/li>\n<\/ul>\n<\/section>\n<p><!-- Section 1 (\u5148\u5207\u5165\u5149\u8def\u53cc\u6298\u5c04\u4e0e\u5185\u5e94\u529b\u63a7\u5236) --><\/p>\n<section id=\"birefringence-control\" style=\"margin-bottom: 50px\">\n<h2 style=\"font-size: 28px;line-height: 1.5em;font-weight: bold;margin-top: 40px;margin-bottom: 24px;color: #111111;border-bottom: 1px solid #eaeaea;padding-bottom: 8px\">Contr\u00f4le de la bir\u00e9fringence et r\u00e9duction des contraintes r\u00e9siduelles dans le PMMA\/PC<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-2793\" src=\"https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/polarized-light-stress-analysis.webp\" alt=\"polarized-light-stress-analysis\" width=\"1376\" height=\"768\" srcset=\"https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/polarized-light-stress-analysis.webp 1376w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/polarized-light-stress-analysis-300x167.webp 300w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/polarized-light-stress-analysis-1024x572.webp 1024w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/polarized-light-stress-analysis-768x429.webp 768w\" sizes=\"auto, (max-width: 1376px) 100vw, 1376px\" \/><\/p>\n<p style=\"font-size: 18px;line-height: 1.8em;text-align: left;margin-bottom: 24px\">Le contr\u00f4le de l'orientation mol\u00e9culaire interne et la pr\u00e9vention des contraintes r\u00e9siduelles lors du <a href=\"https:\/\/www.jcinjectionmolding.com\/fr\/service\/optical-clear-molding\/\"><strong>moulage de plastique optique transparent<\/strong><\/a> n\u00e9cessitent un \u00e9quilibre entre les temp\u00e9ratures de fusion et les vitesses de refroidissement du moule. Des pressions d'injection \u00e9lev\u00e9es et un refroidissement rapide pi\u00e8gent les contraintes de cisaillement \u00e0 l'int\u00e9rieur de la matrice polym\u00e8re, cr\u00e9ant des variations locales de l'indice de r\u00e9fraction connues sous le nom de bir\u00e9fringence. La lumi\u00e8re polaris\u00e9e traversant une lentille optique contrainte subit une double r\u00e9fraction, compromettant la clart\u00e9 optique. Le maintien de temp\u00e9ratures de moule \u00e9lev\u00e9es permet aux cha\u00eenes polym\u00e8res de se d\u00e9tendre avant la solidification, minimisant ainsi les contraintes d'orientation fig\u00e9es. Ralentir la vitesse d'injection pr\u00e8s des points d'injection r\u00e9duit davantage les contraintes de cisaillement localis\u00e9es, \u00e9liminant le blush de carotte et le voile optique.<\/p>\n<\/section>\n<p><!-- Section 2 (\u6df1\u5165 PMMA\/PC\/COC \u7269\u6027\u8868) --><\/p>\n<section id=\"optical-polymers\" style=\"margin-bottom: 50px\">\n<h2 style=\"font-size: 28px;line-height: 1.5em;font-weight: bold;margin-top: 40px;margin-bottom: 24px;color: #111111;border-bottom: 1px solid #eaeaea;padding-bottom: 8px\">R\u00e9sines polym\u00e8res \u00e0 haute transmittance (PMMA, PC optique, COC, COP)<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-2787\" src=\"https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/raw-optical-polymer-granules.webp\" alt=\"raw-optical-polymer-granules\" width=\"1376\" height=\"768\" srcset=\"https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/raw-optical-polymer-granules.webp 1376w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/raw-optical-polymer-granules-300x167.webp 300w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/raw-optical-polymer-granules-1024x572.webp 1024w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/raw-optical-polymer-granules-768x429.webp 768w\" sizes=\"auto, (max-width: 1376px) 100vw, 1376px\" \/><\/p>\n<p style=\"font-size: 18px;line-height: 1.8em;text-align: left;margin-bottom: 24px\">La s\u00e9lection de r\u00e9sines appropri\u00e9es pour le moulage de plastique optique transparent garantit une transmission lumineuse maximale et une endurance thermique. Les polym\u00e8res comme le <strong>PMMA<\/strong> (acrylique) offrent une transmittance lumineuse sup\u00e9rieure \u00e0 92 %, ce qui les rend id\u00e9aux pour les guides de lumi\u00e8re automobiles et les capots d'instruments. Le <a href=\"https:\/\/www.jcinjectionmolding.com\/fr\/materials\/polycarbonate-pc\/\"><strong>polycarbonate (PC) optique<\/strong><\/a> offre une r\u00e9sistance \u00e9lev\u00e9e aux chocs ainsi qu'une transmission de la lumi\u00e8re de 89% pour les capots de capteurs de protection. Les optiques de diagnostic avanc\u00e9es utilisent un copolym\u00e8re d'ol\u00e9fine cyclique (COC) ou un polym\u00e8re d'ol\u00e9fine cyclique (COP) en raison de leur autofluorescence quasi nulle et de leur clart\u00e9 semblable \u00e0 celle du verre.<\/p>\n<p><!-- Table 1: Optical Polymer Comparison Table --><\/p>\n<div style=\"margin: 32px 0\">\n<table style=\"width: 100%;border-collapse: collapse;font-size: 16px;text-align: left;min-width: 600px\">\n<thead>\n<tr style=\"background-color: #f8f9fa;border-bottom: 2px solid #dee2e6\">\n<th style=\"padding: 16px;border: 1px solid #dee2e6;font-weight: 600;color: #111111\">R\u00e9sine polym\u00e8re optique<\/th>\n<th style=\"padding: 16px;border: 1px solid #dee2e6;font-weight: 600;color: #111111\">Transmittance lumineuse (%)<\/th>\n<th style=\"padding: 16px;border: 1px solid #dee2e6;font-weight: 600;color: #111111\">Indice de r\u00e9fraction<\/th>\n<th style=\"padding: 16px;border: 1px solid #dee2e6;font-weight: 600;color: #111111\">Temp\u00e9rature de d\u00e9flexion thermique (\u00b0C)<\/th>\n<th style=\"padding: 16px;border: 1px solid #dee2e6;font-weight: 600;color: #111111\">Application optique principale<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr style=\"border-bottom: 1px solid #dee2e6\">\n<td style=\"padding: 16px;border: 1px solid #dee2e6;color: #333333\">PMMA (Plexiglas 8N)<\/td>\n<td style=\"padding: 16px;border: 1px solid #dee2e6;color: #333333\">&gt; 92%<\/td>\n<td style=\"padding: 16px;border: 1px solid #dee2e6;color: #333333\">1.49<\/td>\n<td style=\"padding: 16px;border: 1px solid #dee2e6;color: #333333\">95\u00b0C<\/td>\n<td style=\"padding: 16px;border: 1px solid #dee2e6;color: #333333\">Guides de lumi\u00e8re automobiles et affichages t\u00eate haute<\/td>\n<\/tr>\n<tr style=\"border-bottom: 1px solid #dee2e6\">\n<td style=\"padding: 16px;border: 1px solid #dee2e6;color: #333333\">PC optique (Makrolon 2407)<\/td>\n<td style=\"padding: 16px;border: 1px solid #dee2e6;color: #333333\">~ 89%<\/td>\n<td style=\"padding: 16px;border: 1px solid #dee2e6;color: #333333\">1.58<\/td>\n<td style=\"padding: 16px;border: 1px solid #dee2e6;color: #333333\">125\u00b0C<\/td>\n<td style=\"padding: 16px;border: 1px solid #dee2e6;color: #333333\">Capots de capteurs de protection et lentilles de phare<\/td>\n<\/tr>\n<tr style=\"border-bottom: 1px solid #dee2e6\">\n<td style=\"padding: 16px;border: 1px solid #dee2e6;color: #333333\">COC (TOPAS 5013) \/ COP<\/td>\n<td style=\"padding: 16px;border: 1px solid #dee2e6;color: #333333\">&gt; 92%<\/td>\n<td style=\"padding: 16px;border: 1px solid #dee2e6;color: #333333\">1.53<\/td>\n<td style=\"padding: 16px;border: 1px solid #dee2e6;color: #333333\">130\u00b0C<\/td>\n<td style=\"padding: 16px;border: 1px solid #dee2e6;color: #333333\">Cuves et lentilles de diagnostic microfluidique<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/section>\n<p><!-- Section 3 (\u5207\u5165 S136 \u955c\u9762\u629b\u5149\u6a21\u5177) --><\/p>\n<section id=\"mirror-polish\" style=\"margin-bottom: 50px\">\n<h2 style=\"font-size: 28px;line-height: 1.5em;font-weight: bold;margin-top: 40px;margin-bottom: 24px;color: #111111;border-bottom: 1px solid #eaeaea;padding-bottom: 8px\">Polissage miroir SPI A-1 et moules en acier inoxydable tremp\u00e9 S136<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-2790\" src=\"https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/diamond-polishing-steel-mold.webp\" alt=\"diamond-polishing-steel-mold\" width=\"1376\" height=\"768\" srcset=\"https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/diamond-polishing-steel-mold.webp 1376w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/diamond-polishing-steel-mold-300x167.webp 300w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/diamond-polishing-steel-mold-1024x572.webp 1024w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/diamond-polishing-steel-mold-768x429.webp 768w\" sizes=\"auto, (max-width: 1376px) 100vw, 1376px\" \/><\/p>\n<p style=\"font-size: 18px;line-height: 1.8em;text-align: left;margin-bottom: 24px\">L'usinage d'aciers de cavit\u00e9 \u00e0 haut poli pour le moulage de plastique transparent optique exige des protocoles d'outillage sp\u00e9cialis\u00e9s. Les surfaces de cavit\u00e9 doivent \u00eatre usin\u00e9es \u00e0 partir d'acier de qualit\u00e9 sup\u00e9rieure <strong>Acier inoxydable S136<\/strong>, trait\u00e9 thermiquement \u00e0 HRC 48-52 pour r\u00e9sister \u00e0 la corrosion et aux rayures microscopiques. Atteindre un <a href=\"https:\/\/www.jcinjectionmolding.com\/fr\/service\/spi-polishing\/\"><strong>poli miroir SPI A-1<\/strong><\/a> n\u00e9cessite un polissage manuel progressif \u00e0 l'aide de p\u00e2tes diamant\u00e9es jusqu'\u00e0 des tailles de particules de 3 microns. Les cavit\u00e9s d'outillage polies miroir \u00e9liminent la microrugosit\u00e9 de surface, assurant un d\u00e9moulage propre sans n\u00e9cessiter de lubrifiants internes liquides.<\/p>\n<p><!-- Numbered List --><\/p>\n<p style=\"font-size: 18px;line-height: 1.8em;text-align: left;margin-bottom: 16px\">Les normes d'outillage optique comprennent :<\/p>\n<ol style=\"font-size: 18px;line-height: 1.8em;margin-bottom: 24px;padding-left: 24px;list-style-type: decimal\">\n<li style=\"margin-bottom: 12px;text-align: left\"><strong>S\u00e9lection de l'acier inoxydable S136<\/strong>\u2014L'utilisation d'acier inoxydable \u00e0 haute teneur en chrome emp\u00eache la micro-piq\u00fbrage caus\u00e9e par l'humidit\u00e9 ambiante ou le d\u00e9gazage.<\/li>\n<li style=\"margin-bottom: 12px;text-align: left\"><strong>Polissage progressif au diamant<\/strong>\u2014Le rodage des surfaces de cavit\u00e9 avec de la p\u00e2te diamant\u00e9e permet d'obtenir une finition miroir optique SPI A-1.<\/li>\n<li style=\"margin-bottom: 12px;text-align: left\"><strong>Optimisation de l'usinage par \u00e9lectro-\u00e9rosion<\/strong>\u2014La fabrication d'\u00e9lectrodes d'EDM en graphite \u00e0 grain fin assure des textures de cavit\u00e9 lisses avant le polissage manuel.<\/li>\n<li style=\"margin-bottom: 12px;text-align: left\"><strong>Configuration de canaux de refroidissement conformes<\/strong>\u2014La configuration des lignes d'eau \u00e0 proximit\u00e9 des surfaces de la cavit\u00e9 optique maintient des temp\u00e9ratures uniformes du noyau de moule.<\/li>\n<\/ol>\n<\/section>\n<p><!-- Section 4 (\u843d\u811a\u5230\u65e0\u5c18\u5ba4\u9632\u9ed1\u70b9\u63a7\u5236) --><\/p>\n<section id=\"cleanroom-dust-control\" style=\"margin-bottom: 50px\">\n<h2 style=\"font-size: 28px;line-height: 1.5em;font-weight: bold;margin-top: 40px;margin-bottom: 24px;color: #111111;border-bottom: 1px solid #eaeaea;padding-bottom: 8px\">Environnement de salle blanche pour \u00e9liminer la poussi\u00e8re et les points noirs<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-2788\" src=\"https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/robotic-optical-part-handling.webp\" alt=\"robotic-optical-part-handling\" width=\"1376\" height=\"768\" srcset=\"https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/robotic-optical-part-handling.webp 1376w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/robotic-optical-part-handling-300x167.webp 300w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/robotic-optical-part-handling-1024x572.webp 1024w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/robotic-optical-part-handling-768x429.webp 768w\" sizes=\"auto, (max-width: 1376px) 100vw, 1376px\" \/><\/p>\n<p style=\"font-size: 18px;line-height: 1.8em;text-align: left;margin-bottom: 24px\">L'ex\u00e9cution du moulage de plastique optique transparent dans des environnements \u00e0 particules contr\u00f4l\u00e9es emp\u00eache la poussi\u00e8re en suspension de s'incruster dans le polym\u00e8re fondu chaud. De minuscules particules de poussi\u00e8re uniques atterrissant sur une surface de lentille chaude cr\u00e9ent des points noirs, provoquant le rejet total de la pi\u00e8ce optique. L'exploitation de cellules de moulage en salle blanche \u00e0 pression positive avec une filtration HEPA \u00e0 plusieurs \u00e9tages maintient une qualit\u00e9 d'air irr\u00e9prochable pendant la plastification et le conditionnement en vrac. Des robots automatis\u00e9s \u00e0 trois axes manipulent directement les lentilles moul\u00e9es, \u00e9liminant les risques de manipulation manuelle et les transferts d'huile cutan\u00e9e.<\/p>\n<\/section>\n<p><!-- FAQ Section --><\/p>\n<section id=\"faq\" style=\"margin-bottom: 40px\">\n<h2 style=\"font-size: 28px;line-height: 1.5em;font-weight: bold;margin-top: 40px;margin-bottom: 24px;color: #111111;border-bottom: 1px solid #eaeaea;padding-bottom: 8px\">Questions fr\u00e9quemment pos\u00e9es (FAQ)<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-2791\" src=\"https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/measuring-plastic-optical-transmittance.webp\" alt=\"measuring-plastic-optical-transmittance\" width=\"1376\" height=\"768\" srcset=\"https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/measuring-plastic-optical-transmittance.webp 1376w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/measuring-plastic-optical-transmittance-300x167.webp 300w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/measuring-plastic-optical-transmittance-1024x572.webp 1024w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/measuring-plastic-optical-transmittance-768x429.webp 768w\" sizes=\"auto, (max-width: 1376px) 100vw, 1376px\" \/><\/p>\n<div style=\"margin-bottom: 30px\">\n<h3 style=\"font-size: 22px;line-height: 1.5em;font-weight: bold;margin-top: 24px;margin-bottom: 12px;color: #111111\">Qu'est-ce qui cause la bir\u00e9fringence dans le moulage de plastique optique ?<\/h3>\n<p style=\"font-size: 18px;line-height: 1.8em;text-align: left;margin-bottom: 24px\">La bir\u00e9fringence est caus\u00e9e par le stress mol\u00e9culaire r\u00e9siduel pi\u00e9g\u00e9 dans le polym\u00e8re lors d'un refroidissement rapide ou d'une injection \u00e0 cisaillement \u00e9lev\u00e9. L'augmentation des temp\u00e9ratures de moule et l'optimisation des profils de pression de maintien permettent aux cha\u00eenes de polym\u00e8re de se d\u00e9tendre, \u00e9liminant la double r\u00e9fraction dans les pi\u00e8ces transparentes.<\/p>\n<\/div>\n<div style=\"margin-bottom: 30px\">\n<h3 style=\"font-size: 22px;line-height: 1.5em;font-weight: bold;margin-top: 24px;margin-bottom: 12px;color: #111111\">Quelle est la diff\u00e9rence entre les finitions de moule SPI A-1 et SPI A-2 ?<\/h3>\n<p style=\"font-size: 18px;line-height: 1.8em;text-align: left;margin-bottom: 24px\">Le poli SPI A-1 repr\u00e9sente la finition miroir optique la plus \u00e9lev\u00e9e, poli avec une p\u00e2te de diamant de 3 microns sur acier tremp\u00e9. Le poli SPI A-2 utilise une p\u00e2te de diamant de 6 microns, laissant des micro-rayures inacceptables pour les lentilles optiques \u00e0 haute transmittance.<\/p>\n<\/div>\n<div style=\"margin-bottom: 0\">\n<h3 style=\"font-size: 22px;line-height: 1.5em;font-weight: bold;margin-top: 24px;margin-bottom: 12px;color: #111111\">Pourquoi le PMMA est-il pr\u00e9f\u00e9r\u00e9 au PC pour les applications de guides de lumi\u00e8re ?<\/h3>\n<p style=\"font-size: 18px;line-height: 1.8em;text-align: left;margin-bottom: 24px\">Le PMMA offre une transmission de la lumi\u00e8re plus \u00e9lev\u00e9e (92% contre 89%) et une dispersion chromatique optique plus faible que le PC. Cependant, le PC est choisi lorsqu'une r\u00e9sistance aux chocs sup\u00e9rieure ou des temp\u00e9ratures de fl\u00e9chissement sous charge plus \u00e9lev\u00e9es sont obligatoires.<\/p>\n<\/div>\n<\/section>\n<\/article>","protected":false},"excerpt":{"rendered":"<p>Flawless light transmission in optical lenses, light pipes, and sensor covers requires strict control over polymer purity and molding thermal dynamics. Microscopic airborne dust particles, surface splay marks, or internal stress-induced birefringence cause light scattering and optical distortion. Manufacturing high-transmittance polymer components relies on cleanroom processing, high-polish mold cavity steels, and precise melt temperature profiling. [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":2792,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-2786","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/www.jcinjectionmolding.com\/fr\/wp-json\/wp\/v2\/posts\/2786","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.jcinjectionmolding.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.jcinjectionmolding.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.jcinjectionmolding.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.jcinjectionmolding.com\/fr\/wp-json\/wp\/v2\/comments?post=2786"}],"version-history":[{"count":0,"href":"https:\/\/www.jcinjectionmolding.com\/fr\/wp-json\/wp\/v2\/posts\/2786\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.jcinjectionmolding.com\/fr\/wp-json\/wp\/v2\/media\/2792"}],"wp:attachment":[{"href":"https:\/\/www.jcinjectionmolding.com\/fr\/wp-json\/wp\/v2\/media?parent=2786"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.jcinjectionmolding.com\/fr\/wp-json\/wp\/v2\/categories?post=2786"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.jcinjectionmolding.com\/fr\/wp-json\/wp\/v2\/tags?post=2786"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}