{"id":2786,"date":"2026-08-01T16:28:27","date_gmt":"2026-08-01T08:28:27","guid":{"rendered":"http:\/\/0"},"modified":"2026-11-21T16:42:13","modified_gmt":"2026-11-21T08:42:13","slug":"specs-for-optical-clear-plastic-molding-lens-clarity","status":"publish","type":"post","link":"https:\/\/www.jcinjectionmolding.com\/de\/blog\/specs-for-optical-clear-plastic-molding-lens-clarity\/","title":{"rendered":"Spezifikationen f\u00fcr optisch klares Kunststoffspritzgie\u00dfen: Linsenklarheit"},"content":{"rendered":"<article style=\"font-family: -apple-system, BlinkMacSystemFont, &apos;Segoe UI&apos;, Roboto, Helvetica, Arial, sans-serif;color: #333333;width: 100%\">\n<section style=\"margin-bottom: 30px\">\n<p style=\"font-size: 18px;line-height: 1.8em;text-align: left;margin-bottom: 24px\">Fehlerfreie Lichtdurchl\u00e4ssigkeit in optischen Linsen, Lichtleitern und Sensorabdeckungen erfordert eine strenge Kontrolle der Polymerreinheit und der thermischen Dynamik des Spritzgie\u00dfens. Mikroskopisch kleine Staubpartikel in der Luft, Oberfl\u00e4chenflie\u00dfmarken oder durch innere Spannungen verursachte Doppelbrechung f\u00fchren zu Lichtstreuung und optischer Verzerrung. Die Herstellung von Polymerkomponenten mit hoher Lichtdurchl\u00e4ssigkeit h\u00e4ngt von Reinraumverarbeitung, hochglanzpolierten Formenst\u00e4hlen und pr\u00e4ziser Schmelztemperaturprofilierung ab. JUCHENG betreibt spezialisierte partikelkontrollierte Fertigungszellen und produziert hochklare optische Kunststoffteile streng nach den technischen Zeichnungen der Kunden.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-2789\" src=\"https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/cleanroom-optical-molding-station.webp\" alt=\"cleanroom-optical-molding-station\" width=\"1376\" height=\"768\" srcset=\"https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/cleanroom-optical-molding-station.webp 1376w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/cleanroom-optical-molding-station-300x167.webp 300w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/cleanroom-optical-molding-station-1024x572.webp 1024w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/cleanroom-optical-molding-station-768x429.webp 768w\" sizes=\"auto, (max-width: 1376px) 100vw, 1376px\" \/><\/p>\n<\/section>\n<p><!-- Table of Contents --><\/p>\n<section style=\"background-color: #f8f9fa;border-left: 4px solid #0056b3;padding: 24px;border-radius: 6px;margin: 40px 0\">\n<h3 style=\"font-size: 22px;font-weight: bold;line-height: 1.5em;margin-top: 0;margin-bottom: 16px;color: #111111\">Inhaltsverzeichnis<\/h3>\n<ul style=\"list-style-type: none;padding-left: 0;margin: 0\">\n<li style=\"margin-bottom: 12px\"><a style=\"color: #0056b3;text-decoration: none;font-size: 17px;font-weight: 500\" href=\"#birefringence-control\">1. Doppelbrechungskontrolle &amp; Reduzierung von Eigenspannungen in PMMA\/PC<\/a><\/li>\n<li style=\"margin-bottom: 12px\"><a style=\"color: #0056b3;text-decoration: none;font-size: 17px;font-weight: 500\" href=\"#optical-polymers\">2. Hochtransparente Polymerharze (PMMA, optisches PC, COC, COP)<\/a><\/li>\n<li style=\"margin-bottom: 12px\"><a style=\"color: #0056b3;text-decoration: none;font-size: 17px;font-weight: 500\" href=\"#mirror-polish\">3. SPI A-1 Spiegelpolitur &amp; geh\u00e4rteter Edelstahl S136 f\u00fcr Formen<\/a><\/li>\n<li style=\"margin-bottom: 0\"><a style=\"color: #0056b3;text-decoration: none;font-size: 17px;font-weight: 500\" href=\"#cleanroom-dust-control\">4. Reinraumumgebung zur Eliminierung von Staub und schwarzen Punkten<\/a><\/li>\n<\/ul>\n<\/section>\n<p><!-- Section 1 (\u5148\u5207\u5165\u5149\u8def\u53cc\u6298\u5c04\u4e0e\u5185\u5e94\u529b\u63a7\u5236) --><\/p>\n<section id=\"birefringence-control\" style=\"margin-bottom: 50px\">\n<h2 style=\"font-size: 28px;line-height: 1.5em;font-weight: bold;margin-top: 40px;margin-bottom: 24px;color: #111111;border-bottom: 1px solid #eaeaea;padding-bottom: 8px\">Doppelbrechungskontrolle &amp; Reduzierung von Eigenspannungen in PMMA\/PC<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-2793\" src=\"https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/polarized-light-stress-analysis.webp\" alt=\"polarized-light-stress-analysis\" width=\"1376\" height=\"768\" srcset=\"https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/polarized-light-stress-analysis.webp 1376w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/polarized-light-stress-analysis-300x167.webp 300w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/polarized-light-stress-analysis-1024x572.webp 1024w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/polarized-light-stress-analysis-768x429.webp 768w\" sizes=\"auto, (max-width: 1376px) 100vw, 1376px\" \/><\/p>\n<p style=\"font-size: 18px;line-height: 1.8em;text-align: left;margin-bottom: 24px\">Managing molecular orientation and reducing residual stress during <a href=\"https:\/\/www.jcinjectionmolding.com\/de\/service\/optical-clear-molding\/\"><strong>optisch klaren Kunststoffspritzgie\u00dfen<\/strong><\/a> requires a process suited to the selected resin and part geometry. Residual stress and frozen-in molecular orientation can make the refractive index depend on the polarization direction. Process changes may reduce this birefringence; verify the finished lens against its specified optical test and acceptance limits. Slowing down injection velocity near the gates further reduces localized shear stresses, eliminating gate blush and optical haze.<\/p>\n<\/section>\n<p><!-- Section 2 (\u6df1\u5165 PMMA\/PC\/COC \u7269\u6027\u8868) --><\/p>\n<section id=\"optical-polymers\" style=\"margin-bottom: 50px\">\n<h2 style=\"font-size: 28px;line-height: 1.5em;font-weight: bold;margin-top: 40px;margin-bottom: 24px;color: #111111;border-bottom: 1px solid #eaeaea;padding-bottom: 8px\">Hochtransparente Polymerharze (PMMA, optisches PC, COC, COP)<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-2787\" src=\"https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/raw-optical-polymer-granules.webp\" alt=\"raw-optical-polymer-granules\" width=\"1376\" height=\"768\" srcset=\"https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/raw-optical-polymer-granules.webp 1376w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/raw-optical-polymer-granules-300x167.webp 300w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/raw-optical-polymer-granules-1024x572.webp 1024w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/raw-optical-polymer-granules-768x429.webp 768w\" sizes=\"auto, (max-width: 1376px) 100vw, 1376px\" \/><\/p>\n<p style=\"font-size: 18px;line-height: 1.8em;text-align: left;margin-bottom: 24px\">The table gives typical supplier values for specific <strong>PMMA<\/strong> (acrylic), <a href=\"https:\/\/www.jcinjectionmolding.com\/de\/materials\/polycarbonate-pc\/\"><strong>Polycarbonat (PC)<\/strong><\/a> and COC grades, not guarantees for finished lenses. R\u00f6hm reports PLEXIGLAS 8N transmittance with D65 under ISO 13468-2; Covestro uses ISO 13468-2; TOPAS reports the listed 2 mm result under ISO 13468-1. Compare grades at the same thickness and test conditions. For COC or COP in fluorescence-sensitive optics, verify background fluorescence for the actual grade and molded part at the intended excitation and detection wavelengths.<\/p>\n<p><!-- Table 1: Optical Polymer Comparison Table --><\/p>\n<div style=\"margin: 32px 0\">\n<table style=\"width: 100%;border-collapse: collapse;font-size: 16px;text-align: left;min-width: 600px\">\n<thead>\n<tr style=\"background-color: #f8f9fa;border-bottom: 2px solid #dee2e6\">\n<th style=\"padding: 16px;border: 1px solid #dee2e6;font-weight: 600;color: #111111\">Optisches Polymerharz<\/th>\n<th style=\"padding: 16px;border: 1px solid #dee2e6;font-weight: 600;color: #111111\">Lichtdurchl\u00e4ssigkeit (%)<\/th>\n<th style=\"padding: 16px;border: 1px solid #dee2e6;font-weight: 600;color: #111111\">Brechungsindex<\/th>\n<th style=\"padding: 16px;border: 1px solid #dee2e6;font-weight: 600;color: #111111\">HDT (\u00b0C, ISO 75 at 0.45 MPa)<\/th>\n<th style=\"padding: 16px;border: 1px solid #dee2e6;font-weight: 600;color: #111111\">Example Application<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr style=\"border-bottom: 1px solid #dee2e6\">\n<td style=\"padding: 16px;border: 1px solid #dee2e6;color: #333333\">PMMA (Plexiglas 8N)<\/td>\n<td style=\"padding: 16px;border: 1px solid #dee2e6;color: #333333\">92% (D65)<\/td>\n<td style=\"padding: 16px;border: 1px solid #dee2e6;color: #333333\">1.49<\/td>\n<td style=\"padding: 16px;border: 1px solid #dee2e6;color: #333333\">103\u00b0C<\/td>\n<td style=\"padding: 16px;border: 1px solid #dee2e6;color: #333333\">Automobil-Lichtleiter &amp; HUD-Displays<\/td>\n<\/tr>\n<tr style=\"border-bottom: 1px solid #dee2e6\">\n<td style=\"padding: 16px;border: 1px solid #dee2e6;color: #333333\">PC (Makrolon 2407)<\/td>\n<td style=\"padding: 16px;border: 1px solid #dee2e6;color: #333333\">89% (2 mm); 88% (3 mm)<\/td>\n<td style=\"padding: 16px;border: 1px solid #dee2e6;color: #333333\">1.584<\/td>\n<td style=\"padding: 16px;border: 1px solid #dee2e6;color: #333333\">136\u00b0C<\/td>\n<td style=\"padding: 16px;border: 1px solid #dee2e6;color: #333333\">Protective covers<\/td>\n<\/tr>\n<tr style=\"border-bottom: 1px solid #dee2e6\">\n<td style=\"padding: 16px;border: 1px solid #dee2e6;color: #333333\">COC (TOPAS 5013S-04)<\/td>\n<td style=\"padding: 16px;border: 1px solid #dee2e6;color: #333333\">91.4% (2 mm)<\/td>\n<td style=\"padding: 16px;border: 1px solid #dee2e6;color: #333333\">1.533<\/td>\n<td style=\"padding: 16px;border: 1px solid #dee2e6;color: #333333\">127\u00b0C<\/td>\n<td style=\"padding: 16px;border: 1px solid #dee2e6;color: #333333\">Optical parts &amp; microfluidic windows<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/section>\n<p><!-- Section 3 (\u5207\u5165 S136 \u955c\u9762\u629b\u5149\u6a21\u5177) --><\/p>\n<section id=\"mirror-polish\" style=\"margin-bottom: 50px\">\n<h2 style=\"font-size: 28px;line-height: 1.5em;font-weight: bold;margin-top: 40px;margin-bottom: 24px;color: #111111;border-bottom: 1px solid #eaeaea;padding-bottom: 8px\">SPI A-1 Spiegelpolitur &amp; S136 geh\u00e4rtete Edelstahlformen<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-2790\" src=\"https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/diamond-polishing-steel-mold.webp\" alt=\"diamond-polishing-steel-mold\" width=\"1376\" height=\"768\" srcset=\"https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/diamond-polishing-steel-mold.webp 1376w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/diamond-polishing-steel-mold-300x167.webp 300w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/diamond-polishing-steel-mold-1024x572.webp 1024w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/diamond-polishing-steel-mold-768x429.webp 768w\" sizes=\"auto, (max-width: 1376px) 100vw, 1376px\" \/><\/p>\n<p style=\"font-size: 18px;line-height: 1.8em;text-align: left;margin-bottom: 24px\">Die Bearbeitung von hochglanzpolierten Kavit\u00e4tenst\u00e4hlen f\u00fcr das Spritzgie\u00dfen von optisch klarem Kunststoff erfordert spezielle Werkzeugbauprotokolle. Kavit\u00e4tenoberfl\u00e4chen m\u00fcssen aus Premium- <strong>S136-Edelstahl<\/strong>, w\u00e4rmebehandelt auf HRC 48-52, bearbeitet werden, um Korrosion und mikroskopische Kratzer zu widerstehen. Um eine <a href=\"https:\/\/www.jcinjectionmolding.com\/de\/service\/spi-polishing\/\"><strong>SPI A-1 Spiegelpolitur<\/strong><\/a> zu erreichen, ist ein progressives Handpolieren mit Diamantpasten bis zu 3-Mikron-Partikelgr\u00f6\u00dfen erforderlich. Spiegelpolierte Werkzeugkavit\u00e4ten eliminieren Oberfl\u00e4chenmikrorauheit und gew\u00e4hrleisten ein sauberes Entformen ohne fl\u00fcssige interne Trennmittel.<\/p>\n<p><!-- Numbered List --><\/p>\n<p style=\"font-size: 18px;line-height: 1.8em;text-align: left;margin-bottom: 16px\">Optische Werkzeugbaustandards umfassen:<\/p>\n<ol style=\"font-size: 18px;line-height: 1.8em;margin-bottom: 24px;padding-left: 24px;list-style-type: decimal\">\n<li style=\"margin-bottom: 12px;text-align: left\"><strong>Auswahl von S136 Edelstahl<\/strong>\u2014Die Verwendung von hochchromhaltigem Edelstahl verhindert Mikrolochfra\u00df, der durch Umgebungsfeuchtigkeit oder Ausgasen verursacht wird.<\/li>\n<li style=\"margin-bottom: 12px;text-align: left\"><strong>Progressives Diamantpolieren<\/strong>\u2014Das L\u00e4ppen von Kavit\u00e4tenoberfl\u00e4chen mit Diamantpaste erreicht eine optische SPI A-1 Spiegeloberfl\u00e4che.<\/li>\n<li style=\"margin-bottom: 12px;text-align: left\"><strong>Optimierung der Funkenerosion<\/strong>\u2014Die Herstellung von EDM-Elektroden aus feink\u00f6rnigem Graphit gew\u00e4hrleistet glatte Kavit\u00e4tentexturen vor dem Handpolieren.<\/li>\n<li style=\"margin-bottom: 12px;text-align: left\"><strong>Konforme K\u00fchlkanalanordnung<\/strong>\u2014Die Konfiguration von Wasserleitungen nahe der optischen Kavit\u00e4tenoberfl\u00e4chen h\u00e4lt gleichm\u00e4\u00dfige Formkerntemperaturen aufrecht.<\/li>\n<\/ol>\n<\/section>\n<p><!-- Section 4 (\u843d\u811a\u5230\u65e0\u5c18\u5ba4\u9632\u9ed1\u70b9\u63a7\u5236) --><\/p>\n<section id=\"cleanroom-dust-control\" style=\"margin-bottom: 50px\">\n<h2 style=\"font-size: 28px;line-height: 1.5em;font-weight: bold;margin-top: 40px;margin-bottom: 24px;color: #111111;border-bottom: 1px solid #eaeaea;padding-bottom: 8px\">Reinraumumgebung zur Eliminierung von Staub und schwarzen Punkten<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-2788\" src=\"https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/robotic-optical-part-handling.webp\" alt=\"robotic-optical-part-handling\" width=\"1376\" height=\"768\" srcset=\"https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/robotic-optical-part-handling.webp 1376w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/robotic-optical-part-handling-300x167.webp 300w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/robotic-optical-part-handling-1024x572.webp 1024w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/robotic-optical-part-handling-768x429.webp 768w\" sizes=\"auto, (max-width: 1376px) 100vw, 1376px\" \/><\/p>\n<p style=\"font-size: 18px;line-height: 1.8em;text-align: left;margin-bottom: 24px\">Die Durchf\u00fchrung von optischem Klarkunststoff-Spritzgie\u00dfen in partikelkontrollierten Umgebungen verhindert, dass sich Luftstaub in die hei\u00dfe Polymerschmelze einbettet. Einzelne mikroskopische Staubpartikel, die auf einer warmen Linsenoberfl\u00e4che landen, erzeugen schwarze Punkte und f\u00fchren zur vollst\u00e4ndigen Ablehnung des optischen Teils. Der Betrieb von Reinraum-Spritzgie\u00dfzellen mit \u00dcberdruck und mehrstufiger HEPA-Filtration gew\u00e4hrleistet eine makellose Luftqualit\u00e4t w\u00e4hrend der Plastifizierung und der Sch\u00fcttgutverpackung. Automatisierte Drei-Achs-Roboter handhaben die geformten Linsen direkt und eliminieren manuelle Handhabungsrisiken und Haut\u00f6l\u00fcbertragungen.<\/p>\n<\/section>\n<p><!-- FAQ Section --><\/p>\n<section id=\"faq\" style=\"margin-bottom: 40px\">\n<h2 style=\"font-size: 28px;line-height: 1.5em;font-weight: bold;margin-top: 40px;margin-bottom: 24px;color: #111111;border-bottom: 1px solid #eaeaea;padding-bottom: 8px\">H\u00e4ufig gestellte Fragen (FAQs)<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-2791\" src=\"https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/measuring-plastic-optical-transmittance.webp\" alt=\"measuring-plastic-optical-transmittance\" width=\"1376\" height=\"768\" srcset=\"https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/measuring-plastic-optical-transmittance.webp 1376w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/measuring-plastic-optical-transmittance-300x167.webp 300w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/measuring-plastic-optical-transmittance-1024x572.webp 1024w, https:\/\/www.jcinjectionmolding.com\/wp-content\/uploads\/2026\/07\/measuring-plastic-optical-transmittance-768x429.webp 768w\" sizes=\"auto, (max-width: 1376px) 100vw, 1376px\" \/><\/p>\n<div style=\"margin-bottom: 30px\">\n<h3 style=\"font-size: 22px;line-height: 1.5em;font-weight: bold;margin-top: 24px;margin-bottom: 12px;color: #111111\">Was verursacht Doppelbrechung beim optischen Kunststoff-Spritzgie\u00dfen?<\/h3>\n<p style=\"font-size: 18px;line-height: 1.8em;text-align: left;margin-bottom: 24px\">Frozen-in molecular orientation and residual stress can contribute to birefringence in molded optics. Appropriate changes to molding conditions may reduce it, but cannot be assumed to eliminate double refraction. Measure the finished part against the specified optical acceptance limits.<\/p>\n<\/div>\n<div style=\"margin-bottom: 30px\">\n<h3 style=\"font-size: 22px;line-height: 1.5em;font-weight: bold;margin-top: 24px;margin-bottom: 12px;color: #111111\">Was ist der Unterschied zwischen SPI A-1 und SPI A-2 Formoberfl\u00e4chen?<\/h3>\n<p style=\"font-size: 18px;line-height: 1.8em;text-align: left;margin-bottom: 24px\">SPI A-1 Politur stellt die h\u00f6chste optische Spiegeloberfl\u00e4che dar, poliert mit 3-Mikron-Diamantpaste auf geh\u00e4rtetem Stahl. SPI A-2 Politur verwendet 6-Mikron-Diamantpaste und hinterl\u00e4sst Mikrokratzer, die f\u00fcr optische Linsen mit hoher Transmission nicht akzeptabel sind.<\/p>\n<\/div>\n<div style=\"margin-bottom: 0\">\n<h3 style=\"font-size: 22px;line-height: 1.5em;font-weight: bold;margin-top: 24px;margin-bottom: 12px;color: #111111\">Warum wird PMMA gegen\u00fcber PC f\u00fcr Lichtleiteranwendungen bevorzugt?<\/h3>\n<p style=\"font-size: 18px;line-height: 1.8em;text-align: left;margin-bottom: 24px\">PMMA can be a good light-guide candidate when clarity matters; PC can be considered when impact resistance or heat performance is important. Compare candidate grades at the same thickness and optical test conditions, compare HDT at the same load, and verify light-guide performance on representative molded parts.<\/p>\n<\/div>\n<\/section>\n<\/article>","protected":false},"excerpt":{"rendered":"<p>Flawless light transmission in optical lenses, light pipes, and sensor covers requires strict control over polymer purity and molding thermal dynamics. Microscopic airborne dust particles, surface splay marks, or internal stress-induced birefringence cause light scattering and optical distortion. Manufacturing high-transmittance polymer components relies on cleanroom processing, high-polish mold cavity steels, and precise melt temperature profiling. [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":2792,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-2786","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/www.jcinjectionmolding.com\/de\/wp-json\/wp\/v2\/posts\/2786","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.jcinjectionmolding.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.jcinjectionmolding.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.jcinjectionmolding.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.jcinjectionmolding.com\/de\/wp-json\/wp\/v2\/comments?post=2786"}],"version-history":[{"count":0,"href":"https:\/\/www.jcinjectionmolding.com\/de\/wp-json\/wp\/v2\/posts\/2786\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.jcinjectionmolding.com\/de\/wp-json\/wp\/v2\/media\/2792"}],"wp:attachment":[{"href":"https:\/\/www.jcinjectionmolding.com\/de\/wp-json\/wp\/v2\/media?parent=2786"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.jcinjectionmolding.com\/de\/wp-json\/wp\/v2\/categories?post=2786"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.jcinjectionmolding.com\/de\/wp-json\/wp\/v2\/tags?post=2786"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}