{"id":2498,"date":"2026-05-30T16:08:43","date_gmt":"2026-05-30T08:08:43","guid":{"rendered":"https:\/\/www.jcinjectionmolding.com\/?p=2498"},"modified":"2026-06-29T16:47:06","modified_gmt":"2026-06-29T08:47:06","slug":"pei-sabic-ultem-hu1000","status":"publish","type":"material_model","link":"https:\/\/www.jcinjectionmolding.com\/de\/materials\/polyetherimide-pei-ultem\/pei-sabic-ultem-hu1000\/","title":{"rendered":"PEI-SABIC Ultem HU1000"},"content":{"rendered":"<div class=\"material-page-wrapper\" style=\"line-height: 1.7 !important;letter-spacing: 0.03em !important;, Arial, sans-serif !important;color: #333333 !important\">\n<p><!-- 3. \u6750\u6599\u4e0b\u5c5e\u578b\u53f7\u4ecb\u7ecd\uff08\u8868\u683c\uff09 --><\/p>\n<section class=\"material-grades\">\n<h2 style=\"font-size: 26px !important;color: #111111 !important;margin-top: 35px !important;margin-bottom: 18px !important;font-weight: 600 !important;letter-spacing: 0.04em !important\">Ultem HU1000 Medizinische Biokompatibilit\u00e4t &amp; Autoklav-Spezifikationen<\/h2>\n<p style=\"margin-bottom: 18px !important;color: #4a4a4a !important\">SABIC\u2122 ULTEM\u2122 Harz HU1000 ist ein unverst\u00e4rktes amorphes Polyetherimid-Harz (PEI) in Healthcare-Qualit\u00e4t, das zertifiziert ist, um herausragende Biokompatibilit\u00e4t und Hochtemperatur-Sterilisationsbest\u00e4ndigkeit gem\u00e4\u00df ISO\/ASTM-Normen zu bieten:<\/p>\n<table style=\"width: 100% !important;border-collapse: collapse !important;margin-top: 20px !important;margin-bottom: 30px !important;border: 1px solid #9cc2c2 !important\">\n<thead>\n<tr>\n<th style=\"background-color: #e6f2f2 !important;color: #111111 !important;font-weight: 600 !important;padding: 14px 18px !important;border: 1px solid #9cc2c2 !important;text-align: left !important;letter-spacing: 0.04em !important;line-height: 1.7 !important\">Biokompatibilit\u00e4ts-\/Sterilisationsspezifikation<\/th>\n<th style=\"background-color: #e6f2f2 !important;color: #111111 !important;font-weight: 600 !important;padding: 14px 18px !important;border: 1px solid #9cc2c2 !important;text-align: left !important;letter-spacing: 0.04em !important;line-height: 1.7 !important\">SABIC Ultem HU1000 Wert<\/th>\n<th style=\"background-color: #e6f2f2 !important;color: #111111 !important;font-weight: 600 !important;padding: 14px 18px !important;border: 1px solid #9cc2c2 !important;text-align: left !important;letter-spacing: 0.04em !important;line-height: 1.7 !important\">MedTech-Montagevorteil<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"padding: 14px 18px !important;border: 1px solid #9cc2c2 !important;color: #4a4a4a !important;line-height: 1.7 !important;font-weight: bold\">Biokompatibilit\u00e4tszertifizierung<\/td>\n<td style=\"padding: 14px 18px !important;border: 1px solid #9cc2c2 !important;color: #4a4a4a !important;line-height: 1.7 !important\">ISO 10993 &amp; USP Klasse VI konform<\/td>\n<td style=\"padding: 14px 18px !important;border: 1px solid #9cc2c2 !important;color: #4a4a4a !important;line-height: 1.7 !important\">Garantiert vollst\u00e4ndige Ungiftigkeit und biologische Sicherheit f\u00fcr kurzzeitigen menschlichen Gewebekontakt und dynamische Fl\u00fcssigkeitswege.<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 14px 18px !important;border: 1px solid #9cc2c2 !important;color: #4a4a4a !important;line-height: 1.7 !important;font-weight: bold\">Autoklav-Hydrolyselebensdauer<\/td>\n<td style=\"padding: 1,000+ autoclave steam cycles limit\">Beh\u00e4lt 100% Struktureigenschaften<\/td>\n<td style=\"padding: 14px 18px !important;border: 1px solid #9cc2c2 !important;color: #4a4a4a !important;line-height: 1.7 !important\">H\u00e4lt wiederholter Dampfsterilisation bei 134\u00b0C stand, ohne Rissbildung, strukturelle Verformung oder Verlust der \u00e4sthetischen Transparenz.<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 14px 18px !important;border: 1px solid #9cc2c2 !important;color: #4a4a4a !important;line-height: 1.7 !important;font-weight: bold\">Chemische Best\u00e4ndigkeit<\/td>\n<td style=\"padding: 14px 18px !important;border: 1px solid #9cc2c2 !important;color: #4a4a4a !important;line-height: 1.7 !important\">Hohe Best\u00e4ndigkeit gegen klinische Lipide und Desinfektionsmittel<\/td>\n<td style=\"padding: 14px 18px !important;border: 1px solid #9cc2c2 !important;color: #4a4a4a !important;line-height: 1.7 !important\">Best\u00e4ndig gegen Spannungsrissbildung bei st\u00e4ndigem Kontakt mit chirurgischen Desinfektionsmitteln, klinischen Kohlenwasserstoffen und aggressiven K\u00f6rperlipiden.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/section>\n<p><!-- 4. \u6750\u6599\u6240\u5e94\u7528\u7684\u5de5\u827a\u4ecb\u7ecd\uff08\u8868\u683c\uff09 --><\/p>\n<section class=\"molding-processes\">\n<h2 style=\"font-size: 26px !important;color: #111111 !important;margin-top: 35px !important;margin-bottom: 18px !important;font-weight: 600 !important;letter-spacing: 0.04em !important\">Klinische Prozesskonfigurationen f\u00fcr biokompatibles Ultem HU1000<\/h2>\n<p style=\"margin-bottom: 18px !important;color: #4a4a4a !important\">Mit standardm\u00e4\u00dfiger Schmelzviskosit\u00e4t und hoher thermischer Stabilit\u00e4t verarbeitet SABIC Ultem HU1000 zuverl\u00e4ssig in medizinischen Hochtemperatursystemen:<\/p>\n<table style=\"width: 100% !important;border-collapse: collapse !important;margin-top: 20px !important;margin-bottom: 30px !important;border: 1px solid #9cc2c2 !important\">\n<thead>\n<tr>\n<th style=\"background-color: #f3f4f6 !important;color: #111111 !important;font-weight: 600 !important;padding: 14px 18px !important;border: 1px solid #9cc2c2 !important;text-align: left !important;letter-spacing: 0.04em !important;line-height: 1.7 !important\">Klinische Anwendungskategorie<\/th>\n<th style=\"background-color: #f3f4f6 !important;color: #111111 !important;font-weight: 600 !important;padding: 14px 18px !important;border: 1px solid #9cc2c2 !important;text-align: left !important;letter-spacing: 0.04em !important;line-height: 1.7 !important\">Prozesskompatibilit\u00e4t &amp; Betriebliche Details<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"padding: 14px 18px !important;border: 1px solid #9cc2c2 !important;color: #4a4a4a !important;line-height: 1.7 !important;font-weight: bold\">Autoklavierbare chirurgische Tabletts<\/td>\n<td style=\"padding: 14px 18px !important;border: 1px solid #9cc2c2 !important;color: #4a4a4a !important;line-height: 1.7 !important\">Ausgezeichnet. Wir formen in unseren Reinr\u00e4umen der ISO-Klasse 7\/8 hochkomplexe Sterilisations-Tabletts, Kassetten und Halterungen f\u00fcr chirurgische Instrumente.<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 14px 18px !important;border: 1px solid #9cc2c2 !important;color: #4a4a4a !important;line-height: 1.7 !important;font-weight: bold\">Hochviskose medizinische Verteiler<\/td>\n<td style=\"padding: 14px 18px !important;border: 1px solid #9cc2c2 !important;color: #4a4a4a !important;line-height: 1.7 !important\">Ausgezeichnet. Hochoptimiert f\u00fcr transparente Medikamentenverteiler, Dialysatorgeh\u00e4use, pharmazeutische Fluidventile und Diagnoserschl\u00e4uche.<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 14px 18px !important;border: 1px solid #9cc2c2 !important;color: #4a4a4a !important;line-height: 1.7 !important;font-weight: bold\">Geh\u00e4use f\u00fcr Diagnoseger\u00e4te<\/td>\n<td style=\"padding: 14px 18px !important;border: 1px solid #9cc2c2 !important;color: #4a4a4a !important;line-height: 1.7 !important\">Gut. Hervorragende strukturelle Festigkeit und geringe Ausgasung erm\u00f6glichen saubere, hochpr\u00e4zise Geh\u00e4use f\u00fcr chirurgische optische Ger\u00e4te und klinische Werkzeuge.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/section>\n<p><!-- 5. \u5236\u9020\u6280\u672f\u6307\u5357 --><\/p>\n<section class=\"manufacturing-guide\">\n<h2 style=\"font-size: 26px !important;color: #111111 !important;margin-top: 35px !important;margin-bottom: 18px !important;font-weight: 600 !important;letter-spacing: 0.04em !important\">ISO 13485 Healthcare-Spritzguss- und Reinheitsmatrix<\/h2>\n<p style=\"margin-bottom: 18px !important;color: #4a4a4a !important\">Das Formen eines amorphen medizinischen Harzes wie Ultem HU1000 erfordert strenge thermische Kontrollen und vollst\u00e4ndige Kontaminationsschutzprotokolle:<\/p>\n<div style=\"border: 1px solid #9cc2c2 !important;margin-top: 20px !important;margin-bottom: 20px !important\">\n<div style=\"background-color: #e6f2f2 !important;padding: 18px !important;border-bottom: 1px solid #9cc2c2 !important\">\n<p style=\"margin-bottom: 0px !important;color: #111111 !important;font-weight: bold;font-size: 15px !important\">Spritzguss im Reinraum der ISO-Klasse 7\/8<\/p>\n<p style=\"margin-top: 8px !important;margin-bottom: 0px !important;color: #4a4a4a !important;font-size: 14px !important\">Medizinisches PEEK und PEI m\u00fcssen vor jeglichen luftgetragenen Partikeln oder Staub gesch\u00fctzt werden. Jucheng betreibt dedizierte Spritzgussmaschinen in vollst\u00e4ndig geschlossenen Reinr\u00e4umen mit \u00dcberdruck der ISO-Klasse 7\/8. Die Rohmaterialzufuhr, Plastifizierung und Roboter-Entnahme der Teile sind vollst\u00e4ndig automatisiert und isoliert.<\/p>\n<\/div>\n<div style=\"background-color: #f3f4f6 !important;padding: 18px !important;border-bottom: 1px solid #9cc2c2 !important\">\n<p style=\"margin-bottom: 0px !important;color: #111111 !important;font-weight: bold;font-size: 15px !important\">Spiegelpolierter S136-Werkzeugstahl (Reinheitserhalt)<\/p>\n<p style=\"margin-top: 8px !important;margin-bottom: 0px !important;color: #4a4a4a !important;font-size: 14px !important\">Um Gewebereizungen durch mikroskopische Oberfl\u00e4chenrauheit zu verhindern, bauen wir Formen aus hochchromhaltigem S136-Edelstahl. Die Kavit\u00e4ten werden mit sauberer Diamantpaste auf ein hohes Niveau spiegelpoliert, wodurch porenfreie biokompatible Teileoberfl\u00e4chen ohne dynamische Auswurfsmarkierungen gew\u00e4hrleistet werden.<\/p>\n<\/div>\n<div style=\"background-color: #e6f2f2 !important;padding: 18px !important;border-bottom: 1px solid #9cc2c2 !important\">\n<p style=\"margin-bottom: 0px !important;color: #111111 !important;font-weight: bold;font-size: 15px !important\">Druck\u00f6l-Formtemperatur-Matrix<\/p>\n<p style=\"margin-top: 8px !important;margin-bottom: 0px !important;color: #4a4a4a !important;font-size: 14px !important\">Um interne thermische Spannungen zu minimieren, werden die Formtemperaturen kontinuierlich bei 140\u00b0C\u2013180\u00b0C (284\u00b0F bis 356\u00b0F) mit Druck\u00f6l-Temperierger\u00e4ten gehalten. Kalte Formen verursachen hohe interne Spannungen, die die Best\u00e4ndigkeit gegen Spannungsrissbildung (ESCR) bei aggressiver klinischer Fl\u00fcssigkeitseinwirkung erheblich beeintr\u00e4chtigen.<\/p>\n<\/div>\n<div style=\"background-color: #f3f4f6 !important;padding: 18px !important\">\n<p style=\"margin-bottom: 0px !important;color: #111111 !important;font-weight: bold;font-size: 15px !important\">Erweitertes Trockenmittel-Vortrocknungsprotokoll<\/p>\n<p style=\"margin-top: 8px !important;margin-bottom: 0px !important;color: #4a4a4a !important;font-size: 14px !important\">PEI ist stark hygroskopisch. Feuchtigkeit verursacht kosmetische Flie\u00dflinien, Blasen und Verlust der transparenten optischen Qualit\u00e4t. Wir trocknen das Rohmaterial in Trockenmitteltrocknern bei 150\u00b0C (302\u00b0F) f\u00fcr 4 Stunden, um den Feuchtigkeitsgehalt vor dem Formen unter 0,02% zu halten und so die dynamischen mechanischen Zugverbindungen zu sch\u00fctzen.<\/p>\n<\/div>\n<\/div>\n<\/section>\n<p><!-- 6. \u4e3b\u8981\u5e94\u7528\u884c\u4e1a\u9886\u57df --><\/p>\n<section class=\"key-applications\">\n<h2 style=\"font-size: 26px !important;color: #111111 !important;margin-top: 35px !important;margin-bottom: 18px !important;font-weight: 600 !important;letter-spacing: 0.04em !important\">Wichtige Anwendungsbereiche f\u00fcr PEI-SABIC Ultem HU1000<\/h2>\n<ul style=\"padding-left: 20px !important;margin-bottom: 25px !important\">\n<li style=\"margin-bottom: 10px !important;color: #4a4a4a !important\"><strong>Chirurgische &amp; Orthop\u00e4dische Systeme:<\/strong> Autoklavierbare chirurgische Sterilisationsschalen, Instrumentenhalterungen, dentale F\u00fchrungsschablonen, chirurgische Bohrschablonen und Laserdiagnose-Verteiler.<\/li>\n<li style=\"margin-bottom: 10px !important;color: #4a4a4a !important\"><strong>Klinisches Fl\u00fcssigkeitsmanagement:<\/strong> H\u00e4modialyse-Dialysatorgeh\u00e4use, pharmazeutische Fl\u00fcssigkeitsventile, IV-Tropfkammern, Fl\u00fcssigkeitsverbinder und Katheteradapter.<\/li>\n<li style=\"margin-bottom: 10px !important;color: #4a4a4a !important\"><strong>Fortschrittliche MedTech-Geh\u00e4use:<\/strong> Geh\u00e4use f\u00fcr chirurgische optische Instrumente, Rahmen f\u00fcr medizinische Monitore, Abdeckungen f\u00fcr Diagnoseger\u00e4te und elektrische Schalteranschl\u00fcsse f\u00fcr Krankenh\u00e4user.<\/li>\n<\/ul>\n<\/section>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Ultem HU1000 Medical Biocompatibility &amp; Autoclave Specs SABIC\u2122 ULTEM\u2122 Resin HU1000 is an unreinforced amorphous Healthcare-grade Polyetherimide (PEI) resin, certified to deliver outstanding biocompatibility and high-heat sterilization resistance under ISO\/ASTM standards: Biocompatibility \/ Sterilization Spec SABIC Ultem HU1000 Value MedTech Assembly Benefit Biocompatibility Certification ISO 10993 &amp; USP Class VI Compliant Guarantees complete non-toxicity and [&hellip;]<\/p>\n","protected":false},"featured_media":2499,"template":"","meta":[],"class_list":["post-2498","material_model","type-material_model","status-publish","has-post-thumbnail","hentry"],"_links":{"self":[{"href":"https:\/\/www.jcinjectionmolding.com\/de\/wp-json\/wp\/v2\/material_model\/2498","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.jcinjectionmolding.com\/de\/wp-json\/wp\/v2\/material_model"}],"about":[{"href":"https:\/\/www.jcinjectionmolding.com\/de\/wp-json\/wp\/v2\/types\/material_model"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.jcinjectionmolding.com\/de\/wp-json\/wp\/v2\/media\/2499"}],"wp:attachment":[{"href":"https:\/\/www.jcinjectionmolding.com\/de\/wp-json\/wp\/v2\/media?parent=2498"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}